Glossary

Function Block

Function blocks define the capabilities of the high level

 

 

measurement and control available in the device.

 

 

There are many possible function block capabilities

 

 

contained in a device such as analog input, discrete

 

 

input, discrete output, signal characterizer, arithmetic,

 

 

integrator, PD or PID control, input selector or analog

 

 

output.

 

 

 

 

Analog Input (AI)

Scanned by the Linking Device.

 

Function Block

 

 

 

 

 

Multiple Analog

Provides up to 8 variables in one function block,

 

Input (MAI)

reducing scan times.

 

Function Block

 

 

 

 

 

Mode

Target - The mode requested by the operator

 

 

Actual - The current mode of the block which may

 

 

differ from the target based on the current operating

 

 

conditions. The actual mode is calculated during block

 

 

execution.

 

 

Permitted - The modes allowed by target during

 

 

operation

 

 

Normal - The desired operating mode of the block.

 

 

 

 

Mode: Out of

In this mode the algorithm of the block is no longer

 

Service

being executed and any outstanding alarms will be

 

 

cleared. This is the highest priority mode.

 

 

 

 

Mode: Auto

In this mode the block algorithm is being executed with

 

 

new value and status as well as mode being computed

 

 

each Macrocycle or execution of the block

 

 

 

 

Mode: Manual

In this mode the block output is not being calculated

 

 

although it may be limited. It is set directly by the

 

 

operator through an interface device.

 

 

 

 

Macrocycle

The period of execution in which the function block

 

 

schedule is defined.

 

 

 

 

Schedule

The rate and relative time which function blocks

 

 

process their inputs and generate their outputs. The

 

 

schedule defines when a function block is triggered to

 

 

start execution

 

 

 

 

Link Master

A link master device is a device that is capable of

 

 

becoming the LAS. There is a bid procedure that is

 

 

followed that selects the link master device with the

 

 

lowest node address.

 

 

 

 

Link Active

The LAS performs five functions:

 

Schedule Device

Maintains the schedule to send compel data (CD)

 

 

messages (DLPDU's) to devices on the network. This

 

 

is the highest priority function.

 

 

 

 

V1.31

page 81 of 85

Page 81
Image 81
Emerson FG-110 manual

FG-110 specifications

The Emerson FG-110 is a versatile and advanced fire and gas detection system designed for industrial applications. With increasing safety and regulatory standards in industries such as oil and gas, chemical processing, and manufacturing, the FG-110 provides a reliable solution for detecting early signs of fire and gas leaks, ensuring the protection of personnel, assets, and the environment.

One of the key features of the Emerson FG-110 is its robust detection capabilities. It is equipped with a variety of sensors for detecting different types of gases, including combustible gases, toxic gases, and oxygen levels. This multi-sensitivity approach allows for enhanced safety in environments where various hazardous substances may be present. The sensors are designed for high accuracy and fast response times, ensuring that any potential issues are detected swiftly before they escalate into more serious incidents.

The Emerson FG-110 utilizes advanced signal processing technologies. This includes sophisticated algorithms that filter out false alarms, providing operators and safety personnel with reliable notifications. The system's ability to distinguish between genuine threats and harmless environmental changes is crucial in high-stakes environments where false alarms can lead to unnecessary disruptions and safety concerns.

One of the standout characteristics of the FG-110 is its modular design, allowing for flexible configurations tailored to specific site requirements. Users can easily integrate additional sensors or modules as their needs evolve or as they expand their facility. This scalability makes it an ideal choice for both new installations and retrofitting existing systems.

In terms of communications, the Emerson FG-110 supports various protocols, enabling seamless integration with existing safety management systems and centralized control rooms. This connectivity enhances real-time monitoring and data analysis, helping safety teams make informed decisions efficiently.

Built with durability in mind, the Emerson FG-110 meets rigorous industrial standards. Its rugged casing and resistance to harsh environmental conditions ensure long-lasting performance, which is essential for operations in environments exposed to extreme temperatures, vibrations, or corrosive substances.

In summary, the Emerson FG-110 fire and gas detection system combines advanced sensor technologies, reliable performance, and modular design to deliver a comprehensive safety solution for industrial applications. With its focus on accuracy, flexibility, and integration, the FG-110 stands out as a robust tool in maintaining safety and preventing hazards in complex industrial environments.