Model NGA2000 TO2
Instruction Manual
SECTION 8
APPENDIX B. USER INTERFACE HELP
This section provides a means of rapidly finding any desired function or configuration factor in the menu system.
The NGA menu system is necessarily complex due to the wide variety of configuration possibili- ties available with the NGA architecture.
Menu Items
This section consists of a series of titles describ- ing the function or configuration desired, with a series of menu titles that show the path taken to that function.
The menu selections are sometimes abbrevi- ated; Basic Controls is referred to as Basic for example, Expert controls and setup as Expert, and Technical level as well as Technical.
ITEM | PATH | NOTES | |
Add a service date | Technical - Service menus - Service history - |
| |
Analyzer module history - Add service date! |
| ||
|
| ||
Alarm enabling | Technical – Listing of all modules – Analog I/O – |
| |
Select I/O module - Relay status |
| ||
|
| ||
Analyzer specific | Expert - Auxiliary module setup - Select Analog | v 2.3 only | |
alarms | output module – Alarm conditions | ||
| |||
Analyzer diagnostics | Technical - Diagnostic menus - Analyzer mod- |
| |
ule diagnostics |
| ||
|
| ||
Analyzer specific con- | Expert - Auxiliary module setup - Select Analog | v 2.3 only | |
trols (remote) | output module – Input line control | ||
| |||
Binding | Technical - System setup – Module Binding |
| |
Displayed parameters | Expert - Analyzer module setup - Displayed pa- |
| |
rameters |
| ||
|
| ||
Electrolyte level | Technical - Diagnostic menus - Analyzer mod- |
| |
ule diagnostics - Physical measurements |
| ||
|
| ||
Exit sleep mode | Basic |
| |
Gas scale factor | Technical - Diagnostic menus - Analyzer mod- |
| |
ule diagnostics - Calibration parameters - Gas |
| ||
| scale factor |
| |
Initiate quick start | Basic |
| |
Last service date | Technical – Service menus – Service history – | User updated | |
Analyzer module history | |||
|
| ||
List of detected NGA | Technical - Listing of all modules | Jumps from there into their | |
modules | diagnostic screens | ||
| |||
Load factory calibration | Technical - Diagnostic menus - Analyzer mod- | Required when changing | |
data | ule diagnostics - Calibration parameters | sensor | |
| Technical – Service menus - Manufacturing |
| |
Manufacturing data | data - Analyzer module data |
| |
Maximum range | Expert - Analyzer module setup - Range set- | Maximum range upper | |
tings | limit | ||
| |||
Minimum range | Expert - Analyzer module setup - Range set- | Minimum range upper limit | |
tings | |||
|
| ||
Power supply voltages | Technical – Diagnostic menus – Analyzer mod- |
| |
ule diagnostics - Power supply voltages |
| ||
|
| ||
Quick start status | Basic |
|
Rosemount Analytical Inc. A Division of Emerson Process Management | Appendix B. User Interface Help |