Monitor: Standard Monitor Functions

The function ByteAddrTest performs a byte-oriented test of the specified memory region. Each location is tested by writing the lowest byte of the location address through the entire memory region and verifying each location.

The function WordAddrTest performs a word-oriented test of the specified memory region. Each location is tested by writing the lowest word of the location address through the entire memory region and verifying each location.

The function LongAddrTest performs a long-oriented test of the specified memory region. Each location is tested by writing the location address through the entire memory region and verifying each location.

The function RotTest performs a long word-oriented test of the specified memory region. Each memory location is tested by rotating a single bit through the long-word location.

The function PingPongAddrTest is used to test the reliability of memory accesses in an envi- ronment where the data addresses are varying widely. The intention is to cause the address buffers and multiplexors to change dramatically.

The function Interact is used to test byte interaction in the memory region specified by StartAddr and EndAddr. The main goal of this test is to check for mirrors in memory. This is accomplished by testing the interaction between bytes at different points in memory.

xprintf

xprintf(CtrlStr, Arg0, Arg1 ... ArgN) char *CtrlStr;

unsigned long Arg0, Arg1, ... ArgN;

xsprintf(Buffer, CtrlStr, Arg0, Arg1 ... ArgN) char *Buffer, *CtrlStr;

unsigned long Arg0, Arg1, ... ArgN;

Description: This function serves as a System V UNIX®-compatible printf() without floating point. It implements all features of %d, %o, %u, %x, %X, %c, and %s. An additional control statement has been added to allow printing of binary values (%b).

The xprintf and xsprintf functions format an argument list according to a control string Ctrl- Str. The function xprintf prints the parsed control string to the console, while the function xsprintf writes the characters to the Buffer. The control string format is a string that con- tains plain characters to be processed as is, and special characters that are used to indicate the format of the next argument in the argument list. There must be at least as many argu- ments as special characters, or the function may act unreliably.

Special character sequences are started with the character %. The characters after the % can provide information about left or right adjustment, blank and zero padding, argument con- version type, precision, and more things too numerous to list.

10002367-02

PmT1 and PmE1 User’s Manual

8-45

Page 119
Image 119
Emerson PMT1, PME1 user manual Xprintf

PMT1, PME1 specifications

The Emerson PME1 and PMT1 are advanced solutions in the realm of process management and automation, designed to enhance the efficiency and effectiveness of industrial operations. These devices play a crucial role in improving process control and providing comprehensive data analysis, which can lead to increased productivity and reduced operational costs.

The PME1 is characterized by its robust design and highly flexible architecture, allowing it to adapt to a variety of industrial environments. It integrates seamlessly with existing systems and offers advanced connectivity options to ensure that data flow is uninterrupted across different platforms. This feature is particularly important in modern industrial settings where data silos can inhibit operational efficiency.

The PMT1, on the other hand, focuses on real-time monitoring and telemetry. Its streamlined interface allows for quick access to key metrics, enabling operators to make informed decisions promptly. This is crucial in processes where timing is essential and minor delays can lead to significant financial losses. The PMT1 supports both wired and wireless communication protocols, ensuring that data is transmitted reliably irrespective of operational conditions.

One of the main features of both the PME1 and PMT1 is their integration of cutting-edge predictive analytics. With machine learning capabilities, these devices can analyze patterns and trends within the data, providing insights that can preemptively address potential issues before they escalate into significant problems. This predictive capability contributes to minimizing downtime and optimizing maintenance schedules, thus enhancing the overall lifecycle of equipment.

Another significant characteristic of the PME1 and PMT1 is their user-friendly interface. The intuitive design allows operators of all skill levels to navigate the systems with ease, minimizing training time and increasing overall productivity. With customizable dashboards, users can tailor their views to highlight the most relevant data for their specific operational needs.

In terms of security, both devices utilize advanced cybersecurity measures to protect sensitive data from unauthorized access. This is becoming increasingly important as industries rely more on digital solutions, and the potential risks associated with data breaches grow.

In summary, the Emerson PME1 and PMT1 are sophisticated tools designed for modern industrial applications, combining powerful features, advanced technologies, and essential characteristics. Their ability to provide real-time data analysis, ensure connectivity, and enhance predictive maintenance makes them invaluable for optimizing process management in various sectors. With a focus on user experience and data security, these devices are set to redefine efficiency and productivity in industrial operations.