PMC/PCI Interface: PCI9060ES Initialization

Table 7-5:PCI9060ES Local Configuration Register Initialization

 

 

Hex Value

 

Local Bus1

 

at the

byte-swapped

 

Address (hex):

Register:

PCI9060ES:

at the CPU:

Notes:

C100,0080

Local Address Space 0

FF800008

080080FF

Memory space reads are prefetchable. The

 

Range

 

 

PCI-to-local range is set to 2MB of on-card

 

 

 

 

DRAM.

 

 

 

 

 

C100,0084

Local Space 0 Local

00000001

01000000

PCI-to-local remap address is 0000,000016.

 

Base Address

 

 

Enable PCI-to-local accesses.

 

 

 

 

 

C100,0088

Local Arbitration

00400000

00004000

Enable PCI direct slave locked sequences.

 

 

 

 

 

C100,008C

Big/Little Endian

00000000

00000000

Little endian ordering.

 

Descriptor

 

 

 

 

 

 

 

 

C100,0090

Local Expansion ROM

00000000

00000000

Disable local expansion ROM.

 

Range (PCI to local

 

 

 

 

bus)

 

 

 

 

 

 

 

 

C100,0094

BREQo Control

00000011

11000000

Slave BREQo delay is 24 clocks. Enable local

 

 

 

 

bus BREQo.

 

 

 

 

 

C100,0098

Local Bus Region

F8030043

430003F8

Memory space local bus width is 32 bits.

 

Descriptor to PCI to

 

 

There are no memory space internal wait

 

Local Accesses

 

 

states. Enable memory space ready input.

 

 

 

 

Disable bterm input and bursting.2 The

 

 

 

 

slave PCI write mode is one. Target retry

 

 

 

 

delay is 120 clocks.

 

 

 

 

 

C100,009C

Local Range

E0000000

000000E0

Local-to-PCI range is 512 MB.

 

(Direct Master to PCI)

 

 

 

 

 

 

 

 

C100,00A0

Local Bus Base

40000000

00000040

PCI memory space is mapped at

 

Address (Direct

 

 

4000,000016.

 

Master to PCI

 

 

 

 

memory)

 

 

 

 

 

 

 

 

C100,00A4

Local Base Address

60000000

00000060

PCI I/O and configuration space is mapped

 

(Direct Master to PCI

 

 

at 6000,000016.

 

I/O/CFG)

 

 

 

 

 

 

 

 

C100,00A8

PCI Base Address

00000007

07000000

Local-to-PCI remap address is 0000,000016.

 

(Remap) (Direct

 

 

Enable master I/O, memory accesses, and

 

Master to PCI)

 

 

lock input.

 

 

 

 

 

C100,00AC

PCI Configuration

00000000

00000000

Local-to-PCI accesses are not converted to

 

Address (Direct

 

 

PCI configuration cycles.

 

Master to PCI IO/CFG)

 

 

 

 

 

 

 

 

1.These registers are initialized by the serial EEPROM.

2.Bursting on the MPC860P’s local bus must remain disabled (i.e., bit 24 of the PCI9060ES’s local register at offset 0x98 must be zero).

10002367-02

PmT1 and PmE1 User’s Manual

7-5

Page 67
Image 67
Emerson PMT1, PME1 user manual 5PCI9060ES Local Configuration Register Initialization

PMT1, PME1 specifications

The Emerson PME1 and PMT1 are advanced solutions in the realm of process management and automation, designed to enhance the efficiency and effectiveness of industrial operations. These devices play a crucial role in improving process control and providing comprehensive data analysis, which can lead to increased productivity and reduced operational costs.

The PME1 is characterized by its robust design and highly flexible architecture, allowing it to adapt to a variety of industrial environments. It integrates seamlessly with existing systems and offers advanced connectivity options to ensure that data flow is uninterrupted across different platforms. This feature is particularly important in modern industrial settings where data silos can inhibit operational efficiency.

The PMT1, on the other hand, focuses on real-time monitoring and telemetry. Its streamlined interface allows for quick access to key metrics, enabling operators to make informed decisions promptly. This is crucial in processes where timing is essential and minor delays can lead to significant financial losses. The PMT1 supports both wired and wireless communication protocols, ensuring that data is transmitted reliably irrespective of operational conditions.

One of the main features of both the PME1 and PMT1 is their integration of cutting-edge predictive analytics. With machine learning capabilities, these devices can analyze patterns and trends within the data, providing insights that can preemptively address potential issues before they escalate into significant problems. This predictive capability contributes to minimizing downtime and optimizing maintenance schedules, thus enhancing the overall lifecycle of equipment.

Another significant characteristic of the PME1 and PMT1 is their user-friendly interface. The intuitive design allows operators of all skill levels to navigate the systems with ease, minimizing training time and increasing overall productivity. With customizable dashboards, users can tailor their views to highlight the most relevant data for their specific operational needs.

In terms of security, both devices utilize advanced cybersecurity measures to protect sensitive data from unauthorized access. This is becoming increasingly important as industries rely more on digital solutions, and the potential risks associated with data breaches grow.

In summary, the Emerson PME1 and PMT1 are sophisticated tools designed for modern industrial applications, combining powerful features, advanced technologies, and essential characteristics. Their ability to provide real-time data analysis, ensure connectivity, and enhance predictive maintenance makes them invaluable for optimizing process management in various sectors. With a focus on user experience and data security, these devices are set to redefine efficiency and productivity in industrial operations.