Emerson PME1, PMT1 user manual Seed, Serial, Error Number Description

Models: PMT1 PME1

1 128
Download 128 pages 13.13 Kb
Page 116
Image 116

Monitor: Standard Monitor Functions

The second parameter, Base, indicates the base address of the data structure to be oper- ated on, and the Size parameter indicates the size of the data structure to be operated on. The Offset parameter specifies the byte offset in the nonvolatile memory device where the data structure is to be stored. An example of how to initialize, store, and recall the example data structure is shown below.

NVOp(NV_OP_CLEAR, &NVEx, sizeof(NVEx), 0);

NVOp(NV_OP_SAVE , &NVEx, sizeof(NVEx), 0);

NVOp(NV_OP_OPEN , &NvEx, sizeof(NVEx), 0);

NVOp(NV_OP_FIX, &NVEx, sizeof(NVEx), 0);

NVOp(NV_OP_SAVE , &NVEx, sizeof(NVEx), 0);

The clear, save, and open operations cause the nonvolatile device to be cleared and filled with the NVEx data structure; then the data structure is filled from nonvolatile memory. The fix and save operation are used to modify the nonvolatile device, which updates the internal data structures and then writes them back to the nonvolatile memory device.

If errors are encountered during the check, save, or compare operations, an error message is returned from the function NVOp. The error codes are listed below:

Table 8-9:NVOP Error Codes

Error:

Number:

Description:

NVE_NONE

0

No errors

 

 

 

NVE_OVERFLOW

1

Nonvolatile device write count exceeded

 

 

 

NVE_MAGIC

2

Bad magic number read from nonvolatile device

 

 

 

NVE_CKSUM

3

Bad checksum read from nonvolatile device

 

 

 

NVE_STORE

4

Write to nonvolatile device failed

 

 

 

NVE_CMD

5

Unknown operation requested

 

 

 

NVE_CMP

6

Data does not compare to nonvolatile device

 

 

 

See also: NVFields.h.

Seed

Seed(Value)

unsigned long Value;

Description: The Seed function sets the initial value for the random number generator command rand.

Serial

char get_c() char get_d() put_c(char ch) put_d(char ch) baud_c(Baud)

8-42

PmT1 and PmE1 User’s Manual

10002367-02

Page 116
Image 116
Emerson PME1, PMT1 user manual Seed, Serial, Error Number Description

PMT1, PME1 specifications

The Emerson PME1 and PMT1 are advanced solutions in the realm of process management and automation, designed to enhance the efficiency and effectiveness of industrial operations. These devices play a crucial role in improving process control and providing comprehensive data analysis, which can lead to increased productivity and reduced operational costs.

The PME1 is characterized by its robust design and highly flexible architecture, allowing it to adapt to a variety of industrial environments. It integrates seamlessly with existing systems and offers advanced connectivity options to ensure that data flow is uninterrupted across different platforms. This feature is particularly important in modern industrial settings where data silos can inhibit operational efficiency.

The PMT1, on the other hand, focuses on real-time monitoring and telemetry. Its streamlined interface allows for quick access to key metrics, enabling operators to make informed decisions promptly. This is crucial in processes where timing is essential and minor delays can lead to significant financial losses. The PMT1 supports both wired and wireless communication protocols, ensuring that data is transmitted reliably irrespective of operational conditions.

One of the main features of both the PME1 and PMT1 is their integration of cutting-edge predictive analytics. With machine learning capabilities, these devices can analyze patterns and trends within the data, providing insights that can preemptively address potential issues before they escalate into significant problems. This predictive capability contributes to minimizing downtime and optimizing maintenance schedules, thus enhancing the overall lifecycle of equipment.

Another significant characteristic of the PME1 and PMT1 is their user-friendly interface. The intuitive design allows operators of all skill levels to navigate the systems with ease, minimizing training time and increasing overall productivity. With customizable dashboards, users can tailor their views to highlight the most relevant data for their specific operational needs.

In terms of security, both devices utilize advanced cybersecurity measures to protect sensitive data from unauthorized access. This is becoming increasingly important as industries rely more on digital solutions, and the potential risks associated with data breaches grow.

In summary, the Emerson PME1 and PMT1 are sophisticated tools designed for modern industrial applications, combining powerful features, advanced technologies, and essential characteristics. Their ability to provide real-time data analysis, ensure connectivity, and enhance predictive maintenance makes them invaluable for optimizing process management in various sectors. With a focus on user experience and data security, these devices are set to redefine efficiency and productivity in industrial operations.