Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing unit. Use only a properly grounded and polarized electric outlet.

ADJUSTING THE THERMOSTAT

Tank temperature is factory preset

approx. 200°

to 200°F, which mixes with cool tap

 

water to produce an output water

 

temperature of approx. 110°F.

 

To reset the tank thermostat to 200°, turn the indicator one notch to the right of vertical.

After adjusting, lift faucet handle for 20 seconds for water to re-heat to the new setting.

To adjust water temperature, turn thermostat dial on the front of the tank clockwise to increase temperature or turn counter clockwise to decrease temperature. Repeat if necessary. All changes should be minimal.

Scalding Hazard: Do not allow water to boil. May result in severe burns.

PROPERTY DAMAGE

Regularly inspect the unit for any signs of leakage. If there are signs of water damage, immediately remove the unit from service.

To avoid water damage from leakage, replace all cut, loose or split tubing.

A drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should be used in those applications where any leakage could cause property damage.

SEASONAL STORAGE/DRAINAGE

Anytime the hot water faucet is not used for extended periods of time, unplug and drain unit. If it is below freezing you will need to unplug the unit and drain it.

Disconnect power from unit.

Turn faucet lever to warm and allow water to flow until it is cool.

Shut the faucet off at the valve.

Remove drain screw located on bottom center of water tank and drain the water into empty pail.

Empty the tank and then reinstall drain screw onto the bottom of tank, turning until snug. Do NOT over tighten.

To place back in working order, fill tank with water and re-connect the plug.

CLEANING THE FAUCET AND TANK

Only use mild cleaners to clean the faucet and plastic components.

Cleaners with acids, abrasives, alkaline or organic solvents will result in deterioration of the plastic components and void the warranty.