Reference Manual

00809-0100-4808, Rev CA June 2008

Rosemount 3051N

Calibration Overview

Complete calibration of the Rosemount 3051N Pressure Transmitter involves the following tasks:

Configure the Analog Output Parameters

Set Process Variable Units (page 2-8)

Set Output Type – Linear or Square Root (page 2-8)

Set the Range Points (page 2-9)

Set Damping (page 2-12)

Calibrate the Sensor

Full Trim (page 2-18)

Zero Trim (page 2-17)

Calibrate the 4–20 mA Output (Digital-to-Analog [D/A] Signal Conversion)

4–20 mA Output Trim (page 2-19)or

4–20 mA Output Trim Using Other Scale (page 2-19)

Figure 2-7illustrates the Rosemount 3051N transmitter data flow. This data flow can be summarized in four major steps:

1.A change in pressure is measured by a change in the sensor output (Sensor Signal).

2.The sensor signal is converted to a digital format that can be understood by the microprocessor (Analog-to-Digital Signal Conversion).

3.Corrections are performed in the microprocessor to obtain a digital representation of the process input (Digital PV).

4.The Digital PV is converted to an analog value (Digital-to-Analog Signal Conversion).

Figure 2-7also identifies the approximate transmitter location for each calibration task. Note that the data flows from left to right, and a parameter change affects all values to the right of the changed parameter.

Not all calibration procedures should be performed for each Rosemount 3051N transmitter. In addition, some procedures are appropriate for bench calibration but should not be performed during field calibration. Table 2-2identifies the recommended calibration procedures for each type of Rosemount 3051N transmitter for both bench and field calibration.

2-15

Page 27
Image 27
Emerson Process Management 3051N manual Calibration Overview, Configure the Analog Output Parameters

3051N specifications

The Emerson Process Management 3051N is a state-of-the-art pressure transmitter that exemplifies precision and reliability in process automation. Designed for a wide range of industrial applications, the 3051N is celebrated for its advanced features, innovative technologies, and robust construction, catering to the evolving needs of process industries.

One of the standout features of the 3051N is its exceptional accuracy. With a standard accuracy rating of ±0.075% of span, it ensures precise pressure measurements, critical for maintaining optimal process conditions. This high level of accuracy makes it suitable for applications in industries such as oil and gas, chemicals, and water treatment, where even minor deviations can lead to significant operational issues.

The 3051N employs Smart Pressure Technology, integrating digital communication capabilities with traditional analog systems. This technology allows for seamless interoperability with existing process control systems, providing users with vital data for diagnostics, calibration, and configuration via HART, FOUNDATION fieldbus, or Profibus protocols. These capabilities lead to enhanced process efficiency and reduced downtime due to effective predictive maintenance.

Another notable characteristic of this transmitter is its robust design. The 3051N is built to endure harsh industrial environments, with a rugged housing that is resistant to corrosive and hazardous conditions. Its wide operating temperature range, typically from -40°C to 85°C, coupled with various diaphragm materials, ensures that it can function effectively across diverse applications.

Moreover, the Emerson 3051N incorporates advanced predictive diagnostics, enabling users to monitor the health of the transmitter continuously. This feature alerts operators to potential issues before they escalate, facilitating proactive maintenance strategies that can significantly lower operational costs.

The flexible configuration options offered by the 3051N also enhance its usability. Users can select from a variety of pressure ranges, process connection types, and electrical connections, making it easy to customize the transmitter to fit specific application needs.

In conclusion, the Emerson Process Management 3051N pressure transmitter is a versatile and highly efficient device that integrates advanced technology with robust design and exceptional accuracy. Its ability to adapt to various industrial demands while providing predictive diagnostics makes it a preferred choice for professionals seeking reliability and precision in process management.