Reference Manual
00809-0100-4808, Rev CA
June 2008 Rosemount 3051N
www.rosemountnuclear.com
Section 5 Specifications and Reference DataNuclear Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 5-1
Performance Specifications . . . . . . . . . . . . . . . . . . . . . . .page 5-3
Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . .page 5-5
Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-8
Materials of Construction . . . . . . . . . . . . . . . . . . . . . . . . .page 5-8
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-10
Configuration Information . . . . . . . . . . . . . . . . . . . . . . . . . page 5-11
NUCLEAR
SPECIFICATIONS Qualified for nuclear use per IEEE Std 344-1987 and IEEE Std 323-1983 (mild
environment) as documented in Rosemount Report D2001019
Seismic
Table 5-1. Seismic Specifications Summary
Model
Range
Code
During Seismic
Accuracy(1)
(1) User-adjustable damping set at ≥ 0.4 s unless otherwise noted.
Post Seismic Accuracy
Specified Seismic Maximum
Working Pressure
Structural
Integrity
3051ND 0 not specified not specified 750 psi (5,2 MPa) Maintained
throughout
specified seismic
disturbance
1(2)
(2) Mounting bracket (Option Code B2, BS, or PM) required for specified “During Seismic Accuracy” performance.
0.75% of URL
(adjustable damping
≥1.6 s)
0.25% of span 2000 psi (13,8 MPa)
2(2) 0.75% of URL
(adjustable damping ≥
0.8 s)
3000 psi (20,7 MPa)
(glass-filled TFE o-ring)
2000 psi (13,8 MPa)
(EP o-ring)
3 0.75% of URL
4 0.25% of URL
5
3051NG 2(2) 0.75% of URL
(adjustable damping
≥0.8 s)
Upper Range Limit
3 0.75% of URL
4 0.25% of URL
5
3051NA 0 not specified not specified
1
2 0.25% of URL 0.25% of span
3
4 3000 psia
(glass-filled TFE o-ring)
2000 psi (13,8 MPa)
(EP o-ring)
Differential
Gauge
Absolute