Reference Manual

00809-0100-4808, Rev CA June 2008

Rosemount 3051N

Appendix A HART Communicator

INTRODUCTION

SAFETY MESSAGES

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 Connections and Hardware . . . . . . . . . . . . . . . . . . . . . . . . page A-5 Rosemount 275 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-7 Menus and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-9 Rosemount 375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-11 Diagnostic Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-14

This appendix provides basic communicator information on both the Rosemount 275 and Rosemount 375 HART Communicators when used with a Rosemount 3051N Smart Pressure Transmitter. The Rosemount 275 and Rosemount 375 HART Communicators are not qualified, but may be used as Measurement and Test Equipment (MTE) as documented in Rosemount Report D2001019.

When the HART Communicator is referenced, it refers to either the Rosemount 275 or Rosemount 375.

This brief appendix will familiarize you with the HART Communicator but is not meant to replace the HART Communicator product manual. For additional information on the HART Communicator, refer to the HART Communicator Product Manual, publication number 00809-0100-4275 (Rosemount 275) or 00375-0047-0001 (Rosemount 375).

NOTE

You may need to upgrade the software in your HART Communicator in order to take advantage of all features of the Rosemount 3051N. If you initiate communication with a Rosemount 3051N using a Communicator that has a previous version of the transmitter Device Descriptors (DDs), the communicator will display the following message:

Notice: Upgrade software to access XMTR function. Continue with old description?

If you select YES, the communicator will communicate properly with the transmitter using the existing Rosemount 3051N DDs. However, software features added since the revision of the DDs in the communicator will not be accessible. If you select NO, the communicator will default to a generic transmitter functionality. Contact Rosemount Nuclear Instruments, Inc. at (952) 949-5210.

Procedures and instructions in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that raises potential safety issues is indicated by a warning symbol (). Refer to the following safety messages before performing an operation preceded by this symbol.

www.rosemountnuclear.com

Page 77
Image 77
Emerson Process Management 3051N manual Appendix a Hart Communicator, Introduction Safety Messages

3051N specifications

The Emerson Process Management 3051N is a state-of-the-art pressure transmitter that exemplifies precision and reliability in process automation. Designed for a wide range of industrial applications, the 3051N is celebrated for its advanced features, innovative technologies, and robust construction, catering to the evolving needs of process industries.

One of the standout features of the 3051N is its exceptional accuracy. With a standard accuracy rating of ±0.075% of span, it ensures precise pressure measurements, critical for maintaining optimal process conditions. This high level of accuracy makes it suitable for applications in industries such as oil and gas, chemicals, and water treatment, where even minor deviations can lead to significant operational issues.

The 3051N employs Smart Pressure Technology, integrating digital communication capabilities with traditional analog systems. This technology allows for seamless interoperability with existing process control systems, providing users with vital data for diagnostics, calibration, and configuration via HART, FOUNDATION fieldbus, or Profibus protocols. These capabilities lead to enhanced process efficiency and reduced downtime due to effective predictive maintenance.

Another notable characteristic of this transmitter is its robust design. The 3051N is built to endure harsh industrial environments, with a rugged housing that is resistant to corrosive and hazardous conditions. Its wide operating temperature range, typically from -40°C to 85°C, coupled with various diaphragm materials, ensures that it can function effectively across diverse applications.

Moreover, the Emerson 3051N incorporates advanced predictive diagnostics, enabling users to monitor the health of the transmitter continuously. This feature alerts operators to potential issues before they escalate, facilitating proactive maintenance strategies that can significantly lower operational costs.

The flexible configuration options offered by the 3051N also enhance its usability. Users can select from a variety of pressure ranges, process connection types, and electrical connections, making it easy to customize the transmitter to fit specific application needs.

In conclusion, the Emerson Process Management 3051N pressure transmitter is a versatile and highly efficient device that integrates advanced technology with robust design and exceptional accuracy. Its ability to adapt to various industrial demands while providing predictive diagnostics makes it a preferred choice for professionals seeking reliability and precision in process management.