Sterling D48160s manual Fasten the Cutting Chamber, Close the Cutting Chamber Safety Interlock

Models: D48160s

1 113
Download 113 pages 21.04 Kb
Page 44
Image 44

SETTINGS AND ADJUSTMENTS

SECTION 4-9

Adjusting or Replacing Bed Knives

FASTEN THE CUTTING CHAMBER

Raise the hold-down clamps to their upright positions

Turn the knobs clockwise until they are tight against the chamber housing.

CLOSE THE CUTTING CHAMBER SAFETY

INTERLOCK

Engage the safety interlock by turning the actuator screw clockwise with a box wrench or

a ratchet wrench

Make sure the screw is fully seated against the top surface of its housing.

When engaged, the interlock closes the electrical control circuit to the motor and allows the machine to run.

RESTART THE GRANULATOR

If necessary to replace the fuses, call an electrician to do it.

UNLOCK AND TURN ON the main power.

Remove the OUT OF SERVICE tag.

Start the granulator by depressing the start pushbutton on the electrical cabinet.