MULTI-ZONE CONDENSER SEQUENCE OF OPERATION

MULTI-ZONE CONDENSER SEQUENCE OF OPERATION

EMI America Series multi-zone heat pump

Heat pump condensers utilize a reversing

condensers are designed to operate with

valve to provide reverse cycle operation.

EMI America Series indoor air handlers.

Therefore the outdoor unit will act as ei-

Both the condenser (outdoor unit) and

ther a condenser or an evaporator there-

evaporator (indoor unit) have a high Volt

by providing comfort cooling or heating to

service connection. Each is to be indepen-

the indoor space. The reversing valve is

dently connected to the electrical service

energized in cooling. Should the valve fail

panel. (See the unit name plate for the cor-

to actuate, the system will default to the

rect breaker type and size). The outdoor

heating mode of operation.

and indoor units are also connected to each

 

other through a low Volt interconnect wiring.

Cooling operation, Multi-zone Heat

A 24V transformer located in the indoor unit

Pump:

provides the low Volt power source.

Cooling mode operation requires that the

The S & T series (S2HA, T2HA, T3HA &

control (either unit mount or remote wall

mount thermostat) make a connection be-

T4HA) is a limited range heat pumps that

tween low-Volt terminals “R” and “Y” along

will provide comfort cooling or heat pump

with “R” and “O”. When the indoor control

operation operate at an outdoor tempera-

is placed in cooling mode, with the set point

ture range between 35°F and 115°F for

temperature below the room temperature,

cooling, 35°F and 75°F for (heat pump)

the reversing valve will energize (R & O)

heating. The outdoor unit is equipped

along with the compressor and outdoor fan

with a thermostat that will switch off the

(R & Y). When the indoor control is satis-

condenser when temperature falls below

fied and the room temperature falls below

35°F. For heat pump mode the condenser

the set temperature, the compressor and

operation will cease and then switch on

fan will de-energize. The EMI indoor unit

the indoor electric heat. For cooling mode,

is equipped with an anti-short cycle timer

condenser operation will cease.

(ASCT) will prevent the compressor from

The S & T series (S2HA, T2HA, T3HA &

re-starting for three minutes.

 

T4HA) limited range heat pump condens-

When the outdoor temperature falls below

ers are designed to operate as a single

35°F, compressor operation will cease.

stage cooling, two stage heating unit. For

 

full operation the unit should be matched

Heating operation, Multi-zone Heat

with an appropriate EMI indoor unit with

Pump:

electric heat and unit mounted controls or

Heating mode operation requires that the

a wall mounted thermostat.

control (either unit mount or remote wall

 

For two stage heating operation the indoor

mount thermostat) make a connection

unit must be equipped with an electric strip

between low-Volt terminals “R” and “Y”

heater.

only. When the indoor control is placed

See the instruction manual for the indoor

in heating mode, with the set point tem-

perature above room temperature, the

unit on the selection of the proper thermo-

compressor and outdoor fan (R & Y) will

stat for the system.

energize. When the indoor control is satis-

Condenser Operation:

fied and the room temperature rises above

the set temperature, the compressor and

The transformer located in the indoor unit

fan will de-energize. The EMI indoor unit

provides 24V, low-Volt control power to the

is equipped with an anti-short cycle timer

condenser (outdoor unit). This can be mea-

(ASCT) will prevent the compressor from

sured across low-Volt terminals “R” and “C”.

re-starting for three minutes.

Multi-zone Heat Pump Condensing Units

20

www.enviromaster.com

Page 20