EMI T2HA DIMENSIONS AND SPECIFICATIONS, specifications may change without notice, Nominal, Line

Models: S2HA T2HA

1 25
Download 25 pages 18.34 Kb
Page 24
Image 24
T2HA DIMENSIONS AND SPECIFICATIONS

T2HA DIMENSIONS AND SPECIFICATIONS

NOTE: All EMI products are subject to ongoing development programs so design and

specifications may change without notice.

SOUND & WEIGHT DATA

Model

Sound

Weight

dBA

Lbs.

 

T2HA8800

70

325

T2HA8400

70

325

T2HA4400

70

325

INTERCONNECTING TUBING SPECS T2HA, T3HA, & T4HA models:

Nominal

Maximum

Maximum

Liquid

Suction

Circuit

Line

Line

Length

Lift

Capacity

OD

OD

 

 

9,000

100’

35’

1/4”

1/2”

12,000

100’

35’

1/4”

1/2”

18,000

100’

35’

3/8”

5/8”

24,000

100’

35’

3/8”

3/4”

T2HA, T3HA, AND T4HA - 208/230V - 60 HERTZ 1 - PHASE

 

FAN MTR

 

 

 

COMPRESSOR

 

 

 

TOTAL

 

HACR

MIN

CAPACITY

 

 

CIRCUIT #1

CIRCUIT #2

CIRCUIT #3

CIRCUIT #4

MCA

AMPS

HP

AMPS

BRKR

VOLT

 

RLA

LRA

RLA

LRA

RLA

LRA

RLA

LRA

 

 

 

 

 

 

 

 

 

 

 

 

 

8800

1.8

0.33

5.4

36.0

5.4

36.0

-

 

-

-

-

12.6

14.0

15.0

197

4400

1.8

0.33

8.8

54.0

8.8

54.0

-

 

-

-

-

19.4

21.6

30.0

197

8400

1.8

0.33

5.4

36.0

8.8

54.0

-

 

-

-

-

16.0

18.2

25.0

197

Circuit Designators: 9 = 9000 Btuh 2 = 12000 Btuh 8 = 18000 Btuh 4 = 24000 Btuh (ex. - 8400 consists of one 18000 Btuh compressor and one 24000 Btuh compressor)

Multi-zone Heat Pump Condensing Units

24

www.enviromaster.com

Page 24
Image 24
EMI T2HA DIMENSIONS AND SPECIFICATIONS, specifications may change without notice, Nominal, Maximum, Liquid, Suction