Lennox International Inc WING manual Specifications Heat Pump

Models: WING

1 34
Download 34 pages 13.61 Kb
Page 10
Image 10

SPECIFICATIONS HEAT PUMP

OUTDOOR UNIT WITH AXIAL FAN

R-22

MODEL

 

 

 

WING

WING

WING

WING

 

 

 

2,8TB

3TB

4TB

5TB

Cooling capacity

(*)

 

W

7.350

9.250

11.600

13.700

Heating capacity

(**)

 

W

7.800

9.000

12.100

14.600

OUTDOOR UNIT

 

 

KJB 2,8

KJB 3

KJB 4

KJB 5

COMPRESSOR

Nª / Type

 

 

1 / ALT.

1 / ALT.

1 / ALT.

1 / ALT.

FAN

 

 

 

 

 

 

 

Air flow outdoor unit

m3/h.

 

3.100

3.100

5.400

5.600

 

 

 

REFRIGERANT

Type / R-22

gr.

 

1775

2500

2800

3500

EXPANSIÓN

 

 

 

Capillary

Capillary

Capillary

Restrictor

WEIGHT

 

Kg

 

81

83

99

129

DIMENSIONS

 

mm.

 

781

781

1035

1330

Height

 

 

 

 

 

 

 

 

1005

Width

 

mm.

 

973

973

973

 

 

 

 

 

 

 

Depth

 

mm.

 

333

333

333

386

PACKING DIMENSIONS

mm.

 

845 x 1060 x 385

1085 x 1275

1495 x 1057

 

x 385

 

 

 

 

 

 

x 430

REFRIGERANT COUPLING

 

 

3/8"

3/8"

3/8"

1/2"

Líquid pipe

 

 

 

Gas pipe

 

 

 

5/8"

3/4"

3/4"

3/4"

INDOOR UNIT

 

LTX 3

LTX 3

LTX 5

LTX 5

FAN

Max.

1.300

1.300

2.100

2.100

Air flow indoor unit

m3/h.

 

 

 

 

 

Min.

1.100

1.100

1.800

1.800

WEIGHT

Kg

40

40

57

57

DIMENSIONS

mm.

 

 

 

 

Height

267

267

312

312

Width

mm.

1.409

1.409

1.719

1.719

 

 

Depth

mm.

656

656

756

756

PACKING DIMENSIONS

mm.

310 x 1430 x 680

352 x 1749 x 776

REFRIGERANT COUPLING

 

 

 

 

Líquid pipe

 

3/8"

3/8"

1/2" (2)

1/2"

Gas pipe

 

3/4" (2)

3/4"

3/4"

3/4"

 

 

DB.- Dry Bulb

(*) Air entry temperature into the indoor unit 27°C DB/19 °C WBWB.- Wet Bulb

(*) Air entry temperature into the outdoor unit 35ºC DB

(**)Air entry temperature into the indoor unit 20°C DB/12 °C WB

(**)Air entry temperature into the outdoor unit 7ºC DB/6ºCWB

(1)Charge of refrigerant, factory charged on outdoor unit. See page 22, to calculate model refrigerant charge

(2)Use the coupling fittings included in indoor unit for refrigerant connection with outdoor unit..

8