SPECIFICATIONS

SET WITH AXIAL FAN OUTDOOR UNIT

 

SOUND LEVEL

 

 

WING 2,8TFK

WING 3TFK

WING 3TB

WING 4TFK

WING 5TFK

 

 

 

 

WING 2TB

WING 4TB

WING 5TB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound

 

Indoor unit

(1)

dBA

41/46 (*)

41/46 (*)

41/46 (*)

43/48 (*)

43/48 (*)

 

pressure

(Lp)

 

 

 

 

 

 

 

 

 

Outdoor unit

(2)

 

 

 

 

 

 

 

 

level

 

dBA

52

55

53

56

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Sound level measured to a distance of 2m from the unit, normal absorption, room size according to unit capacity.

(2)Sound level measured to a distance of 5 m, free space.

(*)High speed / Low speed

ELECTRICAL DATA

 

 

WING 2,8TFK

WING 3TFK

WING 3TB

WING 4TFK

WING 5TFK

WING 5TB

 

 

WING 2TB

 

 

WING 4TB

 

 

Voltage

V/f (50 Hz)

 

230V / 1 Ph

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230V-400V / 3 Ph

 

Nominal total input power

Kw

3,06

3,85

3,70

4,70

5,60

5,90

cooling capacity

Nominal total input power

Kw

2,60

----

3,00

3,90

---

5,00

heat pump

Rated current

 

14,87

19,3

18,3

 

 

 

 

A

 

13,4/8,0

12,8/7,7

18,3/9,1

20,4/10,2

21,5/11,3

Current max.

A

17,9

24,4

23,4

 

 

 

 

 

17,3/10,7

16,5/10,2

21,3/12,1

23,1/11,9

24,4/13,2

 

 

 

Starting current max.

A

91

90

90

 

 

 

 

 

 

 

 

 

 

 

 

78 / 39

78 / 39

106 / 53

124 / 62

124 / 62

OUTDOOR UNIT

 

KJF 2,8K

KJF 3K

KJB 3

KJF 4K

KJF 5K

KJB 5

 

KJB 2,8

KJB 4

 

 

Voltage

V/f (50 Hz)

 

230V / 1 Ph

 

 

 

 

 

 

 

230V-400V / 3 Ph

 

 

 

 

 

 

Nominal total input power

Kw

2,88

3,67

3,52

4,45

5,35

5,65

cooling capacity

Nominal total input power

Kw

2,42

---

2,82

3,65

----

4,75

heat pump

 

 

 

 

 

 

 

Rated current

A

14,05

18,48

17,48

 

 

 

 

13,2/7,1

12,0/6,9

17,2/8,0

19,2/9,0

20,4/10,2

 

 

 

Current max.

A

17,12

23,58

22,60

 

 

 

 

 

 

 

 

 

 

 

 

16,4/9,8

15,7/9,4

20,2/11,0

22,1/10,9

23,3/12,1

Starting current max.

A

91

90

90

 

 

 

 

 

 

106 / 53

 

 

 

 

 

78 / 39

78 / 39

124 / 62

124 / 62

INDOOR UNIT

 

LTX 3

LTX 3

LTX 3

LTX 5

LTX 5

LTX 5

Voltage

V/f (50 Hz)

 

 

230V / 1 Ph

 

 

Nominal total input power

Kw

0,18

0,18

0,18

0,25

0,25

0,25

cooling capacity

Nominal total input power

Kw

0,18

---

0,18

0,25

---

0,25

heat pump

 

 

 

 

 

 

 

Rated current

A

0,82

0,82

0,82

1,14

1,14

1,14

Starting current max.

A

2,46

2,46

2,46

3,42

3,42

3,42

10