Lennox International Inc WING manual Sound Level, SET with Centrifugal FAN Outdoor Unit

Models: WING

1 34
Download 34 pages 13.61 Kb
Page 13
Image 13

SPECIFICATIONS

SET WITH CENTRIFUGAL FAN OUTDOOR UNIT

SOUND LEVEL

 

 

WING 2,8CFK

WING 3CFK

WING 4CFK

WING 5CFK

 

 

WING 2CB

WING 3CB

WING 4CB

WING 5CB

Sound

Indoor unit

(1)

dBA

41/46 (*)

41/46 (*)

43/48 (*)

43/48 (*)

pressure (Lp)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

level

Outdoor unit

(2)

dBA

57

58

60

62

 

 

 

 

 

 

 

 

(1)Sound level measured to a distance of 2m from the unit, normal absorption, duct size and installation according to unit capacity.

(2)Sound level measured to a distance of 5 m, normal absorption, duct size and installation according to unit capacity.

(*) High speed / Low speed

ELECTRICAL DATA

 

WING 2,8CFK

WING 3CFK

WING 4CFK

WING 5CFK

 

 

WING 2CB

WING 3CB

WING 4CB

WING 5CB

Voltage

V/f (50 Hz)

230V / 1 Ph

 

 

 

 

230V-400V / 3 Ph

 

 

 

 

Nominal total input power

Kw

3,07

3,86

5,17

7,00

cooling capacity

 

 

 

 

 

Nominal total input power

Kw

2,77

3,40

4,33

6,40

heat pump

 

 

 

 

 

Rated current

A

14,92

18,3

 

 

 

11,7/5,4

16,6/10,0

22,3/13,3

 

 

 

Current max.

A

19,82

23,4

 

 

 

16,5/10,2

21,9/12,7

24,5/16,7

 

 

 

Starting current max.

A

91

90

 

 

 

78 / 39

106 / 53

124 / 62

 

 

 

OUTDOOR UNIT

 

KCF 2,8K

KCF 3K

KCF 4K

KCF 5K

 

KCB 3S

 

 

KCB 2,8S

KCB 4S

KCB 5S

Voltage

V/f (50 Hz)

230V / 1 Ph

 

 

 

 

230V-400V / 3 Ph

 

 

 

 

Nominal total input power

Kw

2,89

3,68

4,92

6,75

cooling capacity

 

 

 

 

 

Nominal total input power

Kw

2,59

3,22

4,08

6,15

heat pump

 

 

 

 

 

Rated current

 

14,10

17,77

 

 

A

 

10,8/4,5

15,5/8,9

21,2/12,2

 

 

Current max.

A

19,00

22,65

 

 

 

15,7/9,4

20,8/11,60

23,4/15,56

 

 

 

Starting current max.

A

91

90

 

 

 

78 / 39

106 / 53

124 / 62

 

 

 

INDOOR UNIT

 

LTX 3

LTX 3

LTX 5

LTX 5

Voltage

V/f (50 Hz)

 

230V / 1 Ph

 

Nominal total input power

Kw

0,18

0,18

0,25

0,25

cooling capacity

Nominal total input power

Kw

0,18

0,18

0,25

0,25

heat pump

Rated current

A

0,82

0,82

1,14

1,14

Starting current max.

A

2,46

2,46

3,42

3,42

 