Empire Comfort Systems CHG, CHR installation instructions Specifications, Instructions to Installer

Models: CHR CHG

1 12
Download 12 pages 55.82 Kb
Page 3
Image 3

SPECIFICATIONS

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.The owner shall retain this instruction manual for future reference.

3.Installer must have owner fill out and mail warranty card supplied with outdoor gas fireplace.

4.Installer should show owner how to start and operate outdoor gas fireplace.

General Information

This appliance is design certified in accordance with requirement 4.96 US and CGA certification requirement CR97-003 by the Canadian Standards Association as an outdoor gas fireplace. The outdoor gas fireplace shall be installed according to these instructions.

Important

All correspondence should refer to complete Model number, Serial number and type of gas.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Attention: Remove rain cap from top of stack before operating outdoor gas fireplace.

Models

CHR and CHG

 

 

 

Input BTU/HR

Natural Gas

LP Gas

High

35,000

32,000

Medium

23,000

29,000

 

 

 

Low

20,000

27,000

 

 

 

Height

49"

 

 

 

 

Width

23"

 

Gas Inlet

3/8" flare

 

Accessories

 

 

 

 

GHK-12

Quick Disconnect 12 Ft. Hose LP & Nat.

 

 

CHKN-1

Natural Gas Conversion Kit

 

 

CHKT-1

Tank Cover for 20lb. Cylinder

 

 

 

Note: This outdoor gas fireplace is not portable.

Attention: Solid fuels shall not be burned in this outdoor gas fireplace.

Do not use this outdoor gas fireplace if any part has been under water. Immediately call a qualified service technician to inspect the outdoor gas fireplace and to replace any part of the control system and any gas control which has been under water.

PROPANE (LP) GAS WARNINGS

CUSTOMER WARNING:

AVERTISSEMENTS POUR LE CONSOMMATEUR:

• Know the odor of LP Gas. If you hear, see or smell leaking LP

• Savoir reconnaître l’odeur du gaz PL. Si vous entendez un

gas, immediately get everyone away from the cylinder and

sifflement ou si vous sentez une odeur de gaz PL, éloignez

call the Fire Department. Do not attempt repairs.

immédiatement toutes les personnes qui sont près de la bouteille

• LP Gas is heavier than air and may settle in low places while

et appelez le service d’incendie. N’essayez pas de réparer.

dissipating.

• Le gaz PL étant plus lourd que l’air, il peut s’accumuler près

• Contact with the liquid contents of cylinder will cause freeze

du sol avant de se dissiper.

burns to the skin.

• Tout contact de la peau avec la phase liquide de la bouteille

• Do not allow children to tamper or play with cylinder.

causera des brûlures par le froid.

• When not connected for use, keep cylinder valve turned off.

• Ne laissez pas les enfants manipuler ou jouer avec la bouteille.

Self contained outdoor gas fireplaces shall be limited to a

• Lorsque la bouteille n’est pas raccordée à l’appareil, gardez la

cylinder of 20 lb. capacity or less.

soupape de la bouteille fermée. Les radiateurs autonomes pour

• Do not use, store or transport cylinder where it would be

patio doivent utiliser une bouteille d’une capacité maximale de

exposed to high temperatures. Relief valve may open allow-

20 lb. (9kg) ou moins.

ing a large amount of flammable gas to escape.

• Ne pas utiliser, entreposer ou transporter la bouteille en l’ex-

• When transporting, keep cylinder secured in an upright

posant à une température excessive car la soupape de sûreté

position with cylinder valve turned off.

risque de s’ouvrir et de laisser échapper une grande quantité de

 

gaz inflammable.

 

• Pour transporter une bouteille de gaz PL, la maintenir solide-

 

ment fixée en position verticale avec la soupape fermée.

 

 

LP GAS CYLINDER INFORMATION

WARNING: Inspect the fuel supply hose before each use of the outdoor gas fireplace. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the outdoor gas fireplace being put into operation. Contact Em- pire Comfort Systems, Inc. to obtain a replacement fuel supply hose.

LP-gas supply cylinder to be used must be constructed and marked in accordance with the specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.

The cylinder supply system must be arranged for vapor withdrawal.

The cylinder used must include a collar to protect the cylinder valve.

This outdoor gas fireplace shall be used only outdoors in a well- ventilated space and shall not be used in a building, garage or any other enclosed area.

If the outdoor gas fireplace is not in use, the gas must be turned off at the supply cylinder.

Storage of an outdoor gas fireplace indoors is permissible only if the cylinder is disconnected and removed from the outdoor gas fireplace.

Cylinders must be stored outdoors in a well-ventilated area out of the reach of children. Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed area.

The pressure regulator and hose assembly supplied with the out- door gas fireplace must be used. A replacement pressure regulator and hose assembly for this outdoor gas fireplace can be obtained by contacting Empire Comfort Systems, Inc.

CHG/CHR

Page 3

Page 3
Image 3
Empire Comfort Systems CHG, CHR installation instructions Specifications, Instructions to Installer