Empire Comfort Systems DVP42FP7(0,1,2,3)(N,P)-1 Rear Vent Conversion, Vent Systems

Models: DVP42FP3(0,1,2,3)(N,P)-1 DVP42FP9(1,3)(N,P)-1 DVP48FP7(0,1,2,3)(N,P)-1 DVP48FP3(0,1,2,3)(N,P)-1 DVP48FP9(1,3)(N,P)-1 DVP42FP7(0,1,2,3)(N,P)-1

1 56
Download 56 pages 23.53 Kb
Page 10
Image 10
REAR VENT CONVERSION

REAR VENT CONVERSION

VERTICAL VENTING

Note: It is recommended that the flue cover plate tab be pulled outward prior to removal.

This will ensure that the plate is not accidentally dropped inside the rear air chamber.

FLUE COVER PLATE

(See note above) VERTICAL VENTING

INLET VENT COVER PLATE

Note: Discard insulation

&retainer when venting off top of fireplace.

Note: Discard insulation

&retainer when using vertical venting off

INLET VENT COLLAR

FLUE OUTLET

COLLAR

HORIZONTAL VENTING

INLET VENT

HORIZONTAL VENTING COVER PLATE

FLUE COVER PLATE

FLUE INSULATION

INSULATION

VENT SYSTEMS RETAINER

INLET VENT COLLAR

Converting flue take-off to rear venting

When switching out the flue and inlet vent collars to run horizontally off the rear vent, the following steps must be taken.

1.Remove the inlet vent collar (8 screws) and flue collar (4 screws) from the top of the fireplace, and set to the side.

2.Remove the inlet cover plate and flue cover plate located on the back of the fireplace. These will be used to close the top flue and inlet openings.

3.Insert the insulation retainer bracket and insulation into the top

flue pipe before reinstalling the flue cover plate over the top flue with 4 screws.

4.Reinstall the inlet cover plate over the top inlet opening with 4 screws. See illustration above..

5.Install the flue collar assembly to the rear flue with 4 screws.

6.Install the inlet vent collar to the rear of the fireplace with 8 screws.

7.This completes the conversion for a rear vent application. Note: for top vented installations, the insulation and retainer are to be removed from the flue pipe and discarded.

VENT SYSTEMS

The following vent systems are acceptable for use with the DVP (42,48) series fireplaces:

Simpson Duravent® GS 5" - 8", Refer to Page 23

*American Metal Products 5" - 8"

*Selkirk Direct-Temp® 5" - 8"

*Security Secure Vent® 5" - 8"

Empire Flexvent Kit DVVK-5F, Refer to Page 26

*Can not be used in side wall horizontal vent installations in the State of Massachusetts.