Empire Comfort Systems DVP48FP9(1,3)(N,P)-1, DVP48FP3(0,1,2,3)(N,P)-1 Vent System Identification

Models: DVP42FP3(0,1,2,3)(N,P)-1 DVP42FP9(1,3)(N,P)-1 DVP48FP7(0,1,2,3)(N,P)-1 DVP48FP3(0,1,2,3)(N,P)-1 DVP48FP9(1,3)(N,P)-1 DVP42FP7(0,1,2,3)(N,P)-1

1 56
Download 56 pages 23.53 Kb
Page 23
Image 23
VENT SYSTEM IDENTIFICATION

VENT SYSTEM IDENTIFICATION

Installing Vent Components (Figure 36)

Begin the vent system installation by installing the first Simpson Duravent component, 90° elbow to the starting collars or straight pipe on the top of the appliance, then the straight pipe length and then horizontal or vertical termination kit.

NOTE:Allouterconnectionjointsmustbesealedwithaluminum tape, screws or silicone sealant rated above 300°F/149°C. The inner flue joints do not require any sealant.

Simpson Duravent vent system components lock into place by

sliding the concentric pipe section with four (4) equally spaced interior beads onto the appliance collar or previously installed component end with four (4) equally spaced indented sections. When the internal beads of each starting outer pipe line up, rotate pipe section clockwise 90° (approximately 3 inches). The vent pipe is now locked together.

Continue adding components per the pre-planned vent system configuration. Be certain that each succeeding vent component is securely fitted and locked into the preceding component in the vent system.

WALL THIMBLE

(MAXIMUM OF THREE 90 ELBOWS)

(MAXIMUM OF TWO 90 ELBOWS)

Special DV Vent Kits - Simpson Duravent and Empire Comfort Systems, Inc.

Can be purchased from Empire Comfort Systems, Inc.

DVVK-5R

Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to 12 inch wall

 

thickness, Includes SD-1208, SD-1247, and SD-2184

DVVK-5T

Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 4

 

to 6 inch wall thickness, Includes SD-1290, SD-1284, SD-1208

 

and SD-1247

DVVK-5V

Direct Vent Fireplace Vent Kit - Vertical, Includes SD-1291,

 

SD-1253, and SD-1243

 

Figure 36

Special Venting Components

Simpson Dura-Vent

Can be purchased from Simpson Duravent or from

Empire Comfort Systems, Inc.

Part Number

Description

SD-1208

6" Pipe Length

SD-1207

9" Pipe Length

SD-1206

12" Pipe Length

SD-1204

24" Pipe Length

SD-1203

36" Pipe Length

SD-1202

48" Pipe Length

SD-1211

Adjustable Pipe Length 11 - 14 5/8"

SD-1284

Horizontal Square Termination Cap

SD-1250

Vinyl Siding Standoff

SD-1245

45° Elbow

SD-1290

90° Elbow

SD-1249

Wall Firestop

SD-1263

Ceiling Firestop

SD-1243

Roof Flashing - 0/12 to 6/12 Roof Pitch

SD-1253

Storm Collar

SD-91291

High Wind Vertical Top

SD-1281

36" Snorkel

SD-1282

14" Firestop Snorkel

SD-1247

Wall Thimble Firestop

17375-10-0706

Page 23

Page 23
Image 23
Empire Comfort Systems DVP48FP9(1,3)(N,P)-1 Vent System Identification, Installing Vent Components Figure