SR-30 CLEARANCES
When facing the front of the appliance the following | CEILING |
minimum clearances to combustible construction must be |
|
maintained. | SIDE WALL |
|
Left side 8 inches (203mm). Right side 8 inches (203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
36” MIN
8” MIN. | 8” MIN. |
2” MIN
FLOOR
Figure 8
WALL MOUNT INSTALLATION
Refer to Figures 9, 10, 11 and 12 for measurements in order to locate (4) mounting holes on wall. Figures 9, 10, 11 and 12 are the front
views of the heaters.
1.Remove lower louver from casing assembly (2 screws).
2.Remove reflector from casing assembly (2 screws).
3.Remove upper louver from casing assembly (2 screws).
1113/16”
(300mm)
|
| 7 13/16” |
|
1 3/32” | 2” | (198mm) | 2” |
| |||
(28mm) |
| ||
(51mm) |
| (51mm) |
18 7/8”
(479mm)22” (559mm)
OUTLINE OF
OUTER CASING
4 1/32” |
|
(102mm) | 2” MIN (51mm) |
| |
| FLOOR |
MOUNTING HOLE LOCATIONS
VIEWED FROM FRONT OF HEATER
Figure 9
1113/16”
(300mm)
|
| 7 13/16” |
|
1 3/32” | 2” | (198mm) | 2” |
| |||
(28mm) | (51mm) |
| (51mm) |
18 7/8” | 22” |
(479mm) | (559mm) |
OUTLINE OF
OUTER CASING
4 1/32” MIN |
|
(102mm) | 2” MIN (51mm) |
| |
| FLOOR |
MOUNTING HOLE LOCATIONS
VIEWED FROM FRONT OF HEATER
Figure 10