CEILING | CEILING |
| |
SIDE WALL | WINDOW SILL OR SHELF | 12” MAX | |
(305mm) | |||
|
|
24” MIN
(610mm)
24” MIN
(610mm)
14” MIN |
|
| 14” MIN | 0” (0mm) CLEARANCE |
(356mm) | 6” MIN | 6” MIN | (356mm) | TO REAR WALL |
| (152mm) | (152mm) |
|
|
SIDE VIEW
2” MIN
2” MIN(51mm) (51mm)
FLOOR | FLOOR |
Figure 5 | Figure 6 |
SR-18 CLEARANCES
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
CEILING |
|
SIDE WALL |
|
36” (914mm) MIN |
|
6” (152mm) | 6” (152mm) |
MIN | MIN |
2” MIN (51mm)
FLOOR
Figure 7 (SR-18)
Page 9 |