INTRODUCTION

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with unvented room heater.

3.Installer should show owner how to start and operate unvented room

heater.

Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.

This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

General Information

This appliance is design certified in accordance with American National Standards Institute Z21.11.2 by the Canadian Standards Association Laboratories as an Unvented Room Heater and shall be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

WARNING: This appliance is equipped for (natural gas or propane) gas. Field conversion is not permitted.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

Well Head Gas Installations

Some natural gas utilities use “well head” gas. This may affect the Btu output of the unit. Contact the gas company for the heating value.

orifice size.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane and natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.*

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.

High Altitudes

For altitudes/elevations above 2,000 feet (610m) ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Contact the manufacturer or your gas company before changing spud/orifice size.

SPECIFICATIONS

Model

SR-6

SR-10

SR-18

SR-30

Input BTU/HR (KW/H) Five Plaques

30,000 (8.8)

BTU/HR (KW/H) Three Plaques

18,000 (5.3)

18,000 (5.3)

BTU/HR (KW/H) Two Plaques

12,000 (3.5)

BTU/HR (KW/H) One Plaque (Nat. Gas)

6,000 (1.8)

10,000 (2.9)

6,700 (2)

8,000 (2.3)

BTU/HR (KW/H) One Plaque (LP Gas)

6,000 (1.8)

10,000 (2.9)

6,700 (2)

7,000 (2.1)

Height

22” (559mm)

22” (559mm)

22” (559mm)

22” (559mm)

Width

11 7/8” (302mm)

11 7/8” (302mm)

18” (457mm)

24 1/8” (613mm)

Depth

6 1/2” (165mm)

6 1/2” (165mm)

6 1/2” (165mm)

6 1/2” (165mm)

 

 

 

 

 

Gas Inlet

3/8” (10mm)

3/8” (10mm)

3/8” (10mm)

3/8” (10mm)

Accessories

 

 

 

 

Blower

SRB-18

SRB-30

Floor Stand*

SRS-10

SRS-10

SRS-18

SRS-30

*Floor stand can not be used in a bathroom or bedroom installation. SR-6 must be wall mounted in a bathroom or bedroom installa- tion.

*Floor stand can not be used in a bedroom installation. SR-10 must be wall mounted in a bedroom installation.

The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFPA54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space.”

16942-5-0907

Page 5

Page 5
Image 5
Empire Comfort Systems SR-30 installation instructions Introduction, Specifications

SR-30 specifications

Empire Comfort Systems has established itself as a leading manufacturer of heating appliances, and the SR-30 gas stove is a testament to its dedication to quality and efficiency. This model is designed to seamlessly blend comfort with modern aesthetic appeal, making it an ideal choice for various living spaces.

The Empire SR-30 boasts a compact design that measures 30 inches in height, making it suitable for both small and larger rooms. One of its main features is the ability to provide heat without the need for electricity, thanks to its reliable gas-burning technology. This characteristic ensures that the stove can function during power outages, providing peace of mind and warmth even in unpredictable weather conditions.

Equipped with state-of-the-art burner technology, the SR-30 delivers an impressive heat output, ranging between 20,000 and 30,000 BTUs, capable of effectively warming spaces up to 1,200 square feet. The unit is designed with a built-in thermostat and adjustable flame control, allowing users to customize the heat output according to their comfort preferences.

Safety is a priority with the SR-30, which features a safety shut-off system designed to prevent gas leaks and ensure safe operation. The unit is also equipped with a venting system that promotes effective heat distribution while minimizing draft issues, providing a consistent and cozy warmth throughout the room.

The aesthetic design of the SR-30 is another standout feature. With a range of attractive finishes and an array of customizable options, consumers can choose a style that complements their home décor. The large glass viewing area offers a warm, flickering flame, creating an inviting atmosphere that enhances any space.

In terms of installation, the SR-30 is versatile, as it can be direct-vented or installed using a one-pipe venting system, providing options for various home configurations. Additionally, the unit operates quietly, ensuring it will not disrupt conversations or relaxation.

In conclusion, the Empire Comfort Systems SR-30 gas stove is an excellent choice for homeowners seeking an efficient, reliable, and stylish heating solution. With its powerful heating capabilities, safety features, and elegant design, the SR-30 adds warmth and charm to any living environment.