Wiring

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protec- tion against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Blower Motor

The blower motor does not have oiling holes. Do not attempt to oil the blower motor.

Blower Wheel

The blower wheel will collect lint and could require periodic cleaning. If the air output decreases or the noise level increases, it indicates a dirty blower wheel.

To clean blower wheel:

1.Turn OFF gas supply to the heater.

2.Turn OFF electrical supply to the heater.

3.Remove lower louver from casing assembly (2 screws).

4.Remove reflector from casing assembly (2 screws).

5.Remove upper louver from casing assembly (2 screws).

6.Clean blower wheel with a vacuum cleaner.

7.As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing as- sembly.

WARNING:

Unplugging of blower accessory will not stop the heater from cycling. To turn off gas to the unvented heater: Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 125°C wire or its equivalent.

PARTS LIST

INDEX PART DESCRIPTION

NUMBER NUMBER

1R-2396 BLOWER (INCLUDES MOTOR, FAN,

AND FAN HOUSING)

2R-2522 ON/OFF SWITCH

3R-2395 WIRE ASSEMBLY

48720161 BUSHING - HEYCO #SR5KN4

5VF-068 CORD SET ASSEMBLY

6SR-195 BLOWER PAN (SR-18)

78520141 RUBBER GROMMET (4 REQUIRED)

88520142 BRASS BUSHING (4 REQUIRED)

NOT SHOWN SR-218

HARDWARE PACKAGE

 

 

Empire Comfort Systems, Inc.