CLEARANCES
Minimum Wall and Ceiling Clearances | Mantel Clearances for |
30” (762mm)
4” (101mm)
Figure 4 |
|
This fireplace can be installed with zero (0") clearance to |
|
combustible material. |
|
When facing the front of the appliance the minimum clearances to |
|
combustible construction (material) are the following: |
|
1. Clearances from the right side or left side of the fireplace |
|
opening to any combustible wall or material should not be | Figure 5 |
less than 4 inches. | |
2. Clearances from the top of the fireplace opening to the ceiling |
|
should not be less than 30 inches. |
|
COMBUSTIBLE MATERIAL
Do not attach combustible material to the mantel of your fireplace. This is a fire hazard.
No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles.