WIRING | |
Label all wires prior to disconnection when servicing controls. |
Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110 volts. Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all optional switches.
Use the two leads (Brown and Black/Red wires) to attach optional components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked with a millivolt meter
Remote Receiver
Use the following steps to place the remote receiver adjacent to the gas valve.
Attention: The remote receiver bracket is not used in this installation.
1. The remote receiver can not be placed behind the gas valve and burner assembly.
2. When facing the appliance, the remote receiver must be placed to the right of the gas valve and burner assembly.
Note: Do not let remote control receiver come in contact with burner assembly.
On circulating
Refer to remote control installation and operating instructions for more details on remote control.
Figure 20
Page 17 |