OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS

EHL-24-1 for Unvented Gas Fireplace

Model

VF24FP2-1, VF24FP3-1

INSTALLING OPTIONAL BRICK LINER EHL-24-1.

1.Remove screen assembly from fireplace.

2.Remove logs from burner assembly.

3.Insert rear brick liner and (2) side brick liners onto bottom of the inner casing. Align grout lines on rear brick liner with grout lines on side brick liners. You must insert rear brick liner before inserting the (2) side brick liners.

4.Loosen top and bottom 10 x 1/2" screws from each side of firebox.

5.Place the (2) liner mounting brackets over the front edges of the (2) side brick liners. Attach liner mounting brackets to outer casing with (4) four 10 x 1/2" screws from Step 4.

6.Replace logs into burner assembly. Refer to "Log Placement," Page 12.

7.Attach screen assembly to fireplace.

8.Installation of optional brick liner is completed.

PARTS LIST FOR EHL-24-1, BRICK LINER KIT

Part Number

Description

11504

Liner Mounting Bracket - Front, 2 Required

R-5769

Brick Liner - Rear

R-5770

Brick Liner - Side Left

R-5771

Brick Liner - Side Right

20248-2-0806

Page 21

Page 21
Image 21