GAS LINE CONNECTION
The fireplace is designed to accept a gas line for connection to the gas valve. Have the line installed by a qualified service person in accordance with all building codes. Consult local building codes to properly size the gas supply line leading to the connection of the valve. The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided through the side panel(s) of the fireplace. See Figure 14.
Check gas type. Use only the gas type indicated on the rating plate. If the gas listed on the plate is not your type of gas supply, DO NOT INSTALL. Contact your dealer for proper model.
Always use an external regulator to reduce the supply tank pressure to a maximum of 10.5" w.c. (NAT), or 13" w.c. (LP) See page 10.
WARNING: CONNECTION DIRECTLY TO AN
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.