WIRING
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110 volts. Maximum length of 20 feet of 16 AWG two (2) conductor wires should be used with all optional switches.
Use the two leads (Red and Green) to attach optional components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked with a millivolt meter
WIRING DIAGRAM
(OPTIONAL) THERMOSTAT (FACULATIVE) THERMOSTAT
Remote Receiver
Use the following steps to place the remote receiver adjacent to the gas valve.
Attention: The remote receiver bracket is not used in this installation.
1.The remote receiver can not be placed behind the gas valve and burner assembly.
2.When facing the appliance, place the remote receiver next to the gas valve.
Install remote control receiver behind bottom louver.
Refer to remote control installation and operating instructions for more details on remote control.
REMOTE CONTROL RECEIVER/
THERMOSTAT/ CONTROLE E
DISTANCE DU RECEPTEUR
HN
(OPTIONAL) WALL SWITCH | GAS VALVE |
INTERRUPTEUR MURAL | VALVE DE GAZ |
(FACULTATIVE) | REMOTE/OFF/ON SWITCH |
ADISTANCE/OUVERT/ FERME INTERRUPTEUR
(OPTIONAL) REMOTE CONTROL RECEIVER (FACULTATIVE) CONTROLE E DISTANCE DU RECEPTEUR
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
THERMOPILE
PILOT
VEILLEUSE
THERMOCOUPLE (LPG)
THERMOCOUPLE (NATURAL)
REMOTE
OFF
ON
GAS VALVE
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH NUMBER 18, 150°C WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES ORIGINAUX, VENANT DU FABRICANT AVEC CETTE UNITE, DOIT ETRE REMPLACE, VOUS DEVEZ LE REMPLACER AVEC UN FIL ELECTRIQUE DE NUMERO 18,
150 ° C DU L'EQUIVALENT.
Figure 19
Page 23 |