Empire Products DVC-35IPT-1, DVC-35T-1 DVC-35IPTINTERMITTENT PILOT SEQUENCE OF OPERATION

Models: DVC-35T-1 DVC-35IPT-1

1 24
Download 24 pages 12.73 Kb
Page 18
Image 18
DVC-35IPT INTERMITTENT PILOT SEQUENCE OF OPERATION

DVC-35IPT INTERMITTENT PILOT SEQUENCE OF OPERATION

START

SYSTEM CHECK

TRIAL FOR

IGNITION

MAIN BURNER OPERATION

Apply 24 VAC to Appliance

Thermostat

Calls for Heat

Flame Signal

Detected

Internal Check

OK

Pilot Valve Opens Ignitor Powered

Pilot Light and lame is Sensed During Trial For Ignition (1)

Ignitor Off

Main Valve Opens

Flame Signal

Lost?

Thermostat Call for Heat Ends

5 Minute Retry

Delay

Pilot Valve Ignition OFF

Wait for Flame Signal to

Disappear

Pilot Valve Closes

Ignition OFF

3 Second Flame

Failure Recycle

Delay

Main Pilot

Valves Close

Flame Lost More

Than 5 Times in

One Call for Heat

END

Main Pilot Valve

Close

(1)Ignitor will turn OFF about 30 seconds into the trial for ignition if the pilot flame has not lit. It will turn back ON for the final 30 seconds of the 90 second trial for ignition. The pilot valve will be energized during the entire trial for ignition. This is normal operation for this gas ignition system.