SR-10T CLEARANCES

SR-10T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 14 inches (356mm). Maximum horizontal extension of projection above the appliance 12 inches (305mm).

Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

24 " MIN (610mm)

14" MIN

(356mm)6 " MIN6 "MIN

(152mm)(152mm)

2 " MIN (51mm)

Figure 3 (SR-10T)

12" MAX (305mm)

24 " MIN (610mm)

14" MIN

0" (0mm) CLEARANCE

(356mm)

TO REAR WALL

2 " MIN (51mm)

Figure 4 (SR-10T)