SR-18T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

 

36" (914mm) MIN

6" (152mm)

6" (152mm)

MIN

MIN

 

2" (51mm)

MIN

Figure 5 (SR-18T)

SR-30T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 8 inches (203mm). Right side 8 inches (203mm). Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

 

36" (914mm) MIN

8"

8"

(203mm)

(203mm)

MIN

MIN

2"

(51mm)

MIN

Figure 6 (SR-30T)

16009-1-0504

Page 9

Page 9
Image 9