Emulex 355 manual System LEDs

Models: 355

1 72
Download 72 pages 33.15 Kb
Page 10
Image 10

EMULEX MODEL 355 SAN STORAGE SWITCH

CHAPTER 2: SWITCH INSTALLATION

USERS GUIDE

System LEDs

The System LEDs indicate the switch’s status, independent of the port LEDs.

Fault

2 Gb/s

Figure 2-4: System LEDs

Power

Switch Operational

System LEDs

Indication

 

 

Fault

• When lit, one or more of the ports has failed or the internal temperature has

(yellow LED)

exceeded acceptable levels.

 

• When flashing, all ports are operational but another error has occurred. Errors

 

appear in an event log. The level of error severity that will cause flashing to start

 

can be controlled using the config sys fault command in the CLI. The default is

 

level 3, Critical.

 

Note: Whether lit or flashing, the switch will continue to operate. Switch

 

functionality may be impaired depending on the event that triggered the

 

Fault LED. Regardless of the cause, the switch requires immediate

 

attention.

 

 

Power

When lit, the switch is plugged in and the internal power supply is functional.

(green LED)

 

 

 

2 Gb/s

When lit, the switch is set to operate at a speed of 2 Gb/s. When off, the switch is

(green LED)

set to 1 Gb/s.

 

 

Switch

• When lit, indicates that the switch has completed initialization for ports with

Operational

inserted SFPs and that the switch is operational.

(green LED)

• When flashing, the switch has been configured for multiple zones, and one or

 

more zones are up with at least one zone down.

 

If no zones (excluding hard zones) are operational, the LED turns off.

 

 

EMULEX CORPORATION

7

PART NUMBER 00041407-002 REV. B

Page 10
Image 10
Emulex 355 manual System LEDs