Emulex 355 manual Port Information, Pre-Insertion Testing, Following settings are available

Models: 355

1 72
Download 72 pages 33.15 Kb
Page 32
Image 32

EMULEX MODEL 355 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

Port Information

The following settings are available.

Setting

Description

 

 

Smart Setting Name

Displays the name of the Smart Setting. The Smart Setting name will

 

automatically appear in the text box when selected in the scroll menu.

 

 

Smart Setting Type

The topology among switches for a port. Options include:

 

• Initiator or Target Port – the default setting. Should be used when

 

there are no links between switches.

 

• Tree Cascade – designates the port as a tree cascade port. Use

 

this setting when connecting multiple switches together in a tree

 

cascade configuration. Under most conditions, this setting will

 

result in acceptable performance.

 

• String Cascade 1 through String Cascade 4 – designates the string

 

cascade to which a port is assigned. String cascades maintain

 

fairness when two or more InSpeed-based storage switches are

 

serially cascaded. Switch performance may be lower when

 

compared to a tree cascade configuration.

 

 

Pre-Insertion Testing

The following settings are available.

Setting

Description

 

 

Enable Policies/Smart

This policy is the default operating mode for all ports and determines

Insertion

what the switch looks for prior to allowing a port to insert into a zone.

 

When the policy is enabled, an external device is sent an F7

 

Initialization notification by the switch until an F7 Initialization

 

notification is received from the device. Once an F7 Initialization

 

notification is received, the port is inserted in the zone.

 

This policy takes precedence over all other policies. When this policy

 

is disabled, no additional policies are operational, and as long as a

 

port transmits a signal of the correct frequency and amplitude, the

 

port will be allowed in the zone.

 

 

Port Test Before Insertion

This policy ensures that a device on a port is a valid, standards-

 

compliant participant before allowing the device to be inserted into a

 

zone. The device must meet all of the FC-AL requirements along with

 

going through a complete change notification cycle. During the

 

change notification cycle, the device becomes the Initialization Master

 

(IM) and goes through the change notification phases. Once the

 

change notification cycle is complete, the device can be inserted. This

 

process ensures that a bad device is not allowed into the zone.

 

 

EMULEX CORPORATION

29

PART NUMBER 00041407-002 REV. B

Page 32
Image 32
Emulex 355 manual Port Information, Pre-Insertion Testing, Following settings are available