Emulex 355 manual Adjusting the Switch Thresholds, Switch Thresholds page appears

Models: 355

1 72
Download 72 pages 33.15 Kb
Page 27
Image 27

EMULEX MODEL 355 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

Adjusting the Switch Thresholds

The Switch Thresholds page displays a variety of switch threshold settings.

Setting

Description

 

 

Ordered Set Error Threshold

The maximum number of OS errors allowed in a 10-second interval

 

before a port is bypassed. Setting this value to "0" returns it to the

 

factory default setting.

 

This setting is activated on the Port Smart Settings page.

 

 

CRC Error Threshold

The maximum number of CRC errors allowed in a 10-second

 

interval before a port is bypassed. Setting this value to "0" returns it

 

to the factory default setting.

 

This setting is activated on the Port Smart Settings page.

 

 

Bad Zone Recovery Hold Time

The amount of time that the switch keeps the ports in bypass mode

(measured in centi-seconds)

before attempting to re-insert the ports into the zone.

 

This setting is activated on the Advanced Functions One-Step

 

Zoning page.

 

 

Bad Zone Recovery Delay Time

The amount of time that the switch waits after a zone goes down

(measured in seconds)

before attempting to recover the zone.

 

This setting is activated on the Advanced Functions One-Step

 

Zoning page.

 

 

Port Utilization Interval

The length of time between readings of the current port’s

(measured in seconds)

utilization.

 

 

To view the current threshold settings:

Click Advanced Functions > Thresholds > Switch.

The Switch Thresholds page appears.

Figure 3-7: Switch Thresholds page

To change switch thresholds or time intervals:

1.Enter the new value in the appropriate text box. The valid range is displayed next to the text box.

2.Click Submit.

The new value is set.

EMULEX CORPORATION

24

PART NUMBER 00041407-002 REV. B

Page 27
Image 27
Emulex 355 Adjusting the Switch Thresholds, Switch Thresholds page appears, To change switch thresholds or time intervals