EMULEX MODEL 355 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

To change the switch’s network location settings:

1.Click Switch > Configuration.

2.Enter the new value in the appropriate text box.

3.Click Submit.

The Switch Configuration page displays the updated information.

Version Information

The different software and hardware versions include:

Setting

Description

 

 

MAC ID

A unique device address (MAC address) assigned to each switch at the

 

factory. This setting cannot be configured or modified.

 

 

Switch FW Version

The current firmware loaded onto the switch.

 

 

Switch HW Version

The hardware version of the switch. This setting cannot be configured or

 

modified.

 

 

SOC Version

The SOC 320 version that is used in the switch. This setting cannot be

 

configured or modified.

 

 

MIB Version

The proprietary Management Information Base version that is supported

 

through SNMP. This setting cannot be configured or modified.

 

 

Switch Speed

The Switch Speed setting indicates the current speed per port at which the switch is running. All ports operate at the same speed. The default switch speed is set to 2.125 Gb/s.

To change the switch speed:

1.Click Switch > Configuration.

2.Select the desired speed.

Setting

Description

 

 

1 Gb/s

Set switch speed to 1.0625 Gb/s.

 

 

2 Gb/s

Set switch speed to 2.125 Gb/s.

 

 

3. Click Submit.

Blocking ARB

When two ports start a communication session, the Blocking ARB is sent to all other ports trying to communicate with those ports until the connection is terminated. The default setting is "FF". If other connected devices use the "FF" setting for another purpose, select another Blocking ARB value (for example, "FB"). Under normal circumstances, this setting does not need to be modified.

Agent Up Time

The Agent Up Time field displays the duration of time that the switch has been operational. If the switch is rebooted or power is cycled, this value is reset.

The Agent Up Time field is for display purposes and cannot be configured.