Emulex EMULEX manual FCA Utilities Reference Manual, Page

Models: EMULEX

1 36
Download 36 pages 33.21 Kb
Page 20
Image 20
Manual background

Tests:

 

 

emlx_biu [pattern]

- Performs the

Bus Interface Unit test.

emlx_echo <did> [pattern]

- Performs the ECHO test to a specified port id.

emlx_post

- Performs the

Power-On Self Tests.

Parameters:

pattern - 4 byte hex pattern to be used for test. (e.g. 0xA5A5A5A5)

Example:

emlxadm> diag emlx_biu

Result: EMLX_DIAG_BIU: Operation successful.

or

emlxadm> diag emlx_echo fffffc

Result: EMLX_DIAG_ECHO: Operation successful.

or

emlxadm> diag emlx_post

Result: EMLX_DIAG_POST: Operation successful.

Example:

emlxadm> diag code 0x4526

Result: CODE(0x4526): 16 (0x10)

Note: The return status from the HBA is displayed in decimal and hexadecimal if the diagnostic code is valid for the HBA. No interpretation of the return status is provided.

ns

Performs and returns a complete query of the fabric name server.

Example:

emlxadm> ns

Nameserver:

-----------------------------------------------------------------

TYPE:

02

 

PID:

0113E1

 

WWPN:

21000020371938fa

 

PORT_NAME:

(SEAGATE ST39103FC

0004)

WWNN:

20000020371938fa

 

NODE_NAME:

(null)

 

IPA:

ffffffffffffffff

 

IP_ADDR:

0.0.0.0

 

CLASS:

8

 

FC4_TYPES:

 

 

00000100,00000000,00000000,00000000,00000000,00000000,00000000,00000000

-----------------------------------------------------------------

TYPE:

02

 

PID:

0113E2

 

WWPN:

21000020371939a2

 

PORT_NAME:

(SEAGATE ST39103FC

0004)

WWNN:

20000020371939a2

 

NODE_NAME: (null)

 

IPA: ffffffffffffffff

 

IP_ADDR: 0.0.0.0

 

CLASS:

8

 

FC4_TYPES:

 

 

00000100,00000000,00000000,00000000,00000000,00000000,00000000,00000000

FCA Utilities Reference Manual

Page 16

Page 20
Image 20
Emulex EMULEX manual FCA Utilities Reference Manual, Page