Troubleshooting Checklist

Table 4-2 Troubleshooting Checklist (Continued)

Problem

Possible Cause

Recommended Action

 

 

 

Cannot contact

IP address not assigned.

Refer to the MATRIX E5 Series Modules

the module

 

Local Management User’s Guide for the IP

through in-band

 

address assignment procedure.

management.

 

 

Port is disabled.

Enable port. Refer to the MATRIX E5 Series

 

 

 

Modules Local Management User’s Guide

 

 

for instructions to enable/disable ports.

 

 

 

 

No link to device.

1. Verify that all network connections

 

 

between the network management station

 

 

and the module are valid and operating.

 

 

2. If the problem continues, contact Enterasys

 

 

Networks for technical support.

 

 

 

Port(s) goes into

Loop condition detected.

1. Verify that Spanning Tree is enabled.

standby for no

 

Refer to the MATRIX E5 Series Modules

apparent reason.

 

Local Management User’s Guide for the

 

 

instructions to set the type of STA.

 

 

2. Review the network design and delete

 

 

unnecessary loops.

 

 

3. If the problem continues, contact Enterasys

 

 

Networks for technical support.

 

 

 

User parameters

1. Position of Mode switch

1. Reenter the lost parameters as necessary.

(IP address,

(7), NVRAM Reset, was

Refer to the MATRIX E5 Series Modules

Device and

changed sometime

Local Management User’s Guide for the

Module name,

before either cycling

instructions to configure the device

etc.) were lost

power or pressing the

through Local Management.

when the module

RESET button, causing

2. If the problem continues, contact Enterasys

power was cycled

the user-entered

Networks for technical support.

or the front panel

parameters to reset to

 

RESET button

factory default settings.

 

was pressed.

2. Clear NVRAM was set

 

 

through Local

 

 

Management.

 

 

 

 

4-6Troubleshooting

Page 40
Image 40