Connecting AC and RPS-SYS Power
SecureStack A2 Installation Guide 3-17
Figure 3-9 Switch Rear View
3. ObservethepowerCPULED(notshown),locatedonthefrontpanel.Duringthe
initialization,theCPULEDwillstartbyilluminatingsolidamber,thenstartblinking
green,thenblinkingamber,thenblinkinggreenagainuntiltheendofthe
initialization,andthenturnssolidgreen.
Iftheswitchisastandaloneswitch,itwilltakeapproximately30secondsforthe
switchtostartup.IftheswitchisastackManager,itcantakeupto3minutesormore
tostartup,dependingonthenumberofMemberswitchesinthestack.
1AC power cord 2AC power connector 3Connector for external redundant power supply
Note: If the CPU LED illuminates solid red, there was a critical failure. For more
information about the LED indications and troubleshooting, refer to Chapter 4. If you need
additional help, contact Enterasys Networks. Refer to “Getting Help” on page1-6 for
details.
MAC ADDRESSSERIAL NO.
AC LINE
100-240 VAC
50-60 Hz
1 A MAX.
Redundant Power Supply
DC Line 12V /13A MAX.
AC LINE
100-240 VAC
50-60 Hz
1 A MAX
À
Á
Â