Using LANVIEW

 

Figure 4-2 LANVIEW LEDs

 

 

 

 

 

 

 

LED

Color

State

Recommended Action

 

 

 

 

 

 

CPU

Off

Power disconnected.

If the LED remains off after connecting AC

 

 

 

 

power or DC power from an RPS, check

 

 

 

 

the following:

 

 

 

 

1. Make sure there is power at the

 

 

 

 

power source (AC source and RPS if

 

 

 

 

applicable).

 

 

 

 

2. Replace the power cord with a known

 

 

 

 

good one or check the continuity of

 

 

 

 

the power cord.

 

 

 

 

3. If the switch still does not power up,

 

 

 

 

the system may have a fatal error.

 

 

 

 

Contact Enterasys Networks for

 

 

 

 

technical support.

 

 

 

 

 

 

 

Red

Solid. Boot-up failed.

If the LED remains red for several

 

 

 

 

minutes, the system may have a fatal

 

 

 

 

error. Contact Enterasys Networks for

 

 

 

 

technical support.

 

 

 

 

 

 

 

Amber

Solid. Diagnostics are running.

If the LED remains amber for more than

 

 

 

 

several minutes, contact

 

 

 

 

Enterasys Networks for technical support.

 

 

 

 

 

 

 

 

Blinking. Code image is being downloaded.

None.

 

 

 

 

 

 

Green Solid. System is fully functional.

None.

 

 

 

 

 

 

 

 

Blinking. Boot-up in process.

None.

 

 

 

 

 

 

DOWN

Off

No valid connection to switch stackup connector.

1. Make sure the switch connected to

 

 

 

 

the stackup connector is powered on.

 

 

 

 

2. Replace cable with a known good

 

 

 

 

one.

 

 

 

 

3. If the problem still exists, contact

 

 

 

 

Enterasys Networks for technical

 

 

 

 

support.

 

 

 

 

 

 

Green Solid. Valid connection to switch stackup

None.

 

 

 

connector.

 

 

Blinking. Information is being transferred via the high-speed stacking cable.

SecureStack C2 Installation Guide 4-3

Page 59
Image 59
Enterasys Networks C2K122-24 manual Lanview LEDs, Color State Recommended Action