Troubleshooting Checklist

Table 4-1 Troubleshooting Checklist (continued)

Problem

Possible Cause

Recommended Action

 

 

 

Cannot contact the

IP address not assigned.

Refer to the SecureStack C2 Configuration Guide for the IP

switch through in-

 

address assignment procedure.

band management.

 

 

Port is disabled.

This is normal if the switch is a Member in a stack.

 

 

 

If operating as a standalone switch or as the Manager in a

 

 

stack, enable the port. Refer to the SecureStack

 

 

C2 Configuration Guide for instructions to enable/disable

 

 

ports.

 

 

 

 

No link to device.

Verify that all network connections between the network

 

 

management station and the device are valid and operating.

 

 

If the problem continues, contact Enterasys Networks for

 

 

technical support.

 

 

 

Port(s) goes into

Loop condition detected.

Verify that Spanning Tree is enabled. Refer to the

standby for no

 

SecureStack C2 Configuration Guide for the instructions to

apparent reason.

 

set the type of STA.

 

 

Review the network design and delete unnecessary loops.

 

 

If the problem continues, contact Enterasys Networks for

 

 

technical support.

 

 

 

User parameters (IP

Clear NVRAM was set using

Reenter the lost parameters as necessary. Refer to the

address, device and

CLI commands.

SecureStack C2 Configuration Guide for the instructions to

module name, etc.)

 

configure the switch using CLI commands.

were lost when the

 

If the problem continues, contact Enterasys Networks for

switch power was

 

 

technical support.

cycled.

 

 

 

 

 

 

4-6 Troubleshooting