| Navigation |
|
|
|
|
|
|
|
|
|
|
Configuration Name |
| Description |
| Default |
SECURE MAIL | Toggles between OUT and IN. Determines the |
| OUT | |
OUT/IN | orientation of the mailslot when the SECURE |
|
| |
| configuration is set to IN. When set to OUT, the mailslot |
|
| |
| remains in its normal orientation. When set to IN, the |
|
| |
| mailslot rotates in, making it inaccessible. |
|
| |
|
|
|
| |
POWER SECURE | Toggles between ON and OFF. The ON configuration |
| POWER | |
ON/OFF | retains your selection of the SECURE MS configuration |
| SECURE OFF | |
| through power cycling (or power outage). The OFF |
|
| |
| configuration allows the jukebox to return to the default |
|
| |
| setting of this configuration after a power cycling. |
|
| |
|
|
|
| |
REP RECOVERED | Toggles between ON and OFF. When set to ON, |
| REP | |
ON/OFF | recovered errors are reported; when set to OFF, |
| RECOVERED | |
| recovered errors are not reported. |
| ON | |
|
|
|
|
|
CONF40 ON/OFF |
|
|
| NA |
| Caution: Changing this configuration may | |||
|
|
|
| |
|
| result in a service call. Used by service |
|
|
|
| personnel only. |
|
|
|
|
|
|
|
|
|
|
|
|
Setting an operating configuration
READY > ADMIN* > CONFIG*
To set an operating configuration:
1.With READY displaying on the control panel, press NEXT until ADMIN* displays.
2.Enter the administration password (see “Entering the administration menu password” on page 34).
3.TEST* displays. Press NEXT until CONFIG* displays and then press
ENTER.
4.Press NEXT or PREV until the name of the configuration you want to set displays and then press ENTER.
If the configuration has multiple settings, the current setting flashes. Proceed to step 5. Otherwise, the configuration is set and a confirmation message displays.
HP StorageWorks 1000ux/1900ux/2300ux Optical Jukebox User’s Guide | 39 |