Navigation

Table 7: Internal tests (Continued)

Test Name

Description

FILL PICKER

Used by service personnel only. Do not run this test if the

 

jukebox contains disks with file system data on them.

 

Moves a disk into the disk transport mechanism from the first

 

storage slot containing a disk. This test must be run twice to

 

fill both containers in the disk transport mechanism.

 

 

EXERCISE MECH

Runs the VERTICAL TEST, TRANSLATE TEST, FLIP

 

TEST, MAGAZINE IO, DRIVE IO, and MAILSLOT IO

 

tests. Each test runs one time per test loop.

 

 

WELLNESS TEST

Checks the general capability of the jukebox. Requires one

 

loaded disk. The drives, transport, and mailslot must be

 

empty. Runs INIT MECHANICS and EXERCISE

 

MECHANICS. Each test runs one time per test loop.

 

 

CLEAR SOFT LOG

Used by service personnel only. Sets the soft error log to

 

zero.

 

 

CLEAR HARD LOG

Used by service personnel only. Sets the hard error log to

 

zero.

 

 

PLUNGE FULL SPD

Allows the disk transport mechanics to run at full speed. This

 

setting should always be used in normal jukebox operation.

 

 

PLUNGE 1/2 SPD

Used by service personnel only.

 

Allows the disk transport mechanics to run at half speed.

 

 

PLUNGE 1/4 SPD

Used by service personnel only.

 

Allows the disk transport mechanics to run at quarter speed.

 

 

MAILSLOT

Displays the current state of the mailslot sensors. If a sensor

SENSORS

is not blocked, a “0” is displayed. If a sensor is blocked, an

 

“*” is displayed. The display automatically updates when the

 

status changes.

 

 

STARWARS

The display shows 0 0 0.

 

Each “0" indicates one of the paths that the disk transport

 

mechanism follows in front of each stack of optical disks. If

 

the path is clear, a “0” displays; if the path is blocked

 

(because of an optical disk that is not inserted fully into its

 

storage slot for example), an “*” will be displayed. This

 

display is automatically updated if the status changes.