Physical Specifications

Physical Specifications

The physical specifications for the RBT‐8200 Wireless Switch are listed in Table 1‐3.

Table 1-3 Physical Specifications

Parameter

Approximate Specification

 

 

Width

430 mm (16.93 in.)

 

 

Height

87.5 mm (3.445 in.)

 

 

Depth

672 mm (26.457 in.)

 

 

Environmental Requirements

Ensure that the environmental requirements are within the ranges described in Table 1‐4.

Table 1-4 Environmental Specifications

Parameter

Description

 

 

Operating Temperature

10°C to 35°C (50°F to 95°F) with the maximum rate of change not to

 

exceed 10°C per hour

 

 

Non-Operating Temperature

40°C to 70°C (104°F to 158°F)

 

 

Altitude

-60 meters (-197 feet) below sea level to 4000 meters (13,123 feet)

 

above sea level

 

 

Non-Operating humidity

90%, non-condensing @ 35°C (95°F)

 

 

Acoustic noise

Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office

 

ambient temperature. (23 +/- degrees C)

 

Sound Power: 7.0 BA in an idle state at typical office ambient

 

temperature. (23 +/- 2 degrees C)

 

 

Operating Shock

No errors with a half sine wave shock of 2G (with 11 millisecond

 

duration).

 

 

Package Shock

Operational after a 24 -inch free fall, although cosmetic damage may

 

be present (chassis weight 40-80 lbs)

 

 

ESD

+/-15kV per Intel Environmental test specification

 

 

System Cooling

1826 BTU/hour

Requirement in BTU/Hr

 

 

 

RBT-8200 Wireless Switch Installation Guide 1-5

Page 19
Image 19
Enterasys Networks RBT-8200 manual Physical Specifications, Environmental Requirements