Network Cable Requirements

Copper

Figure 2-1 specifies the cable types and length constraints for the various copper interfaces on the VH-4802.

Table 2-1. Copper Cable Specifications

Interface Type

Cable Requirement

Maximum Length

10Base-T

Category 3 or 5 Unshielded Twisted

100m (328 ft.)

 

Pair (UTP)

 

100Base-TX

Category 5 UTP

100m (328 ft.)

 

 

 

Fiber

Figure 2-2 specifies the fiber types, bandwidth requirements, and length constraints for the Fast Ethernet fiber interface on the fiber optic media modules.

Table 2-2. Fast Ethernet Fiber Specifications

Interface Type

Fiber Type

Fiber Diameter

Maximum Length (m)

 

 

(microns)

 

100Base-FX (SC

multi-mode

62.5

2,000m (6,560 ft.)

connectors)

 

 

 

100Base-FX (SC

single-mode

10

10 km (6.21 miles)

connectors)

 

 

 

Figure 2-3 specifies the fiber types, bandwidth requirements, and length constraints for the Gigabit Ethernet short-wavelength fiber interface on the fiber optic media module.

Table 2-3. 1000Base-SX Fiber Specifications

Fiber Diameter

Modal Bandwidth @ 850 nm

Range

(microns)

 

 

62.5 µm MMF

160 MHz/km

2-220 Meters

62.5 µm MMF

200 MHz/km

2-275 Meters

50 µm MMF

400 MHz/km

2-500 Meters

50 µm MMF

500 MHz/km

2-550 Meters

 

 

 