Enviro 1700, 1200 owner manual Installing Heat Shield

Models: 1700 1200

1 48
Download 48 pages 14.89 Kb
Page 20
Image 20

Installation

LEGS AND ASH PAN INSTALLATION - FREESTANDING:

Place the unit on the pallet on its back.

Attach pedestal spacer to bottom of the unit, using the supplied screws.

Attach the air channel box to the front of the pedestal spacer using two (2) T-20 screws.

Slide the ash pan assembly over the bolts, using the key-holed slots provided, and tighten all four

(4)bolts.

Carefully remove the cast iron legs from the packaging and secure each leg with two (2) bolts provided.

Secure all four (4) legs, push the

Figure 15: Installing Legs and Ash Pan Assembly.

leg towards the center of the stove and align the legs with the outer edges of the firebox.

Stand the unit on the legs and set the unit in the location ready for installation.

INSTALLATION OF HEAT-EFFICIENCY SHIELD - FREESTANDING FLAT TOP:

The heat-efficiency shield is installed to lower the clearances to combustibles on the flat top freestanding model.

1.The unit must be in position for the installation and with the venting ready to be assembled.

2.Loosen the two (2) top screws on the back of the unit using a 5/16” socket.

3.Place the heat-efficiency shield on top of unit.

4.Slide chimney connector through the heat-efficiency shield and over the flue.

5.Lift the heat-efficiency shield and screw the chimney connector to the flue.

6.Slide the heat-efficiency shield down and hook the slot at the back of the shield, around the loosened screws at the back of the unit.

7.Tighten the two (2) screws at the back.

������� ���������

���� ������

����

������ ������

Figure 16: Installing Heat Shield.