Enviro 1200, 1700 owner manual Metal TAG this Fireplace has Been

Models: 1700 1200

1 48
Download 48 pages 14.89 Kb
Page 29
Image 29

 

Installation

 

 

 

 

 

 

 

 

 

 

The flue collar is removable for

 

 

 

installations into fireplaces with low

 

 

 

openings.

 

 

 

 

 

 

 

 

 

a)

Remove the first two (2) front

 

 

 

 

secondary air tube and ceramic

 

 

 

 

baffles, if

installed

(see

CERAMIC

 

 

 

 

BAFFLE INSTALLATION).

 

 

 

 

 

 

 

b)

Unscrew the nut on top of the

 

 

 

 

inside of the firebox, using a 9/16

 

USA 16” (406 mm)

 

 

wrench or socket (see Figure 32).

 

CND 18” (450 mm)

 

The flue plate clamp will slide off

 

 

 

 

 

 

8"

 

the hook/clamp.

 

 

 

 

 

Floor Protection

c)

Pull the hook/bolt and the

 

(203 mm)

Masonry Fireplace

Combustible Floor

 

 

removable flue collar off the top

 

 

of the unit.

 

 

 

 

 

Figure 30: Insert Installation into existing fireplace without

 

 

 

 

 

 

d)

Attach the flue collar to the venting

 

hearth.

 

 

 

 

 

pipe using sheet metal screws.

 

 

 

e)

Push the unit into place while

 

 

 

 

trying to keep the collar attached

 

 

 

 

to venting close to the opening on

 

 

 

 

the top of the unit.

 

 

 

 

 

 

f)

Using the hook/bolt, grab the

 

 

 

 

flue collar by the rod through the

 

 

 

 

center and pull it into place (see

 

 

 

 

Figure 33).

 

 

 

 

 

 

USA 16” (406 mm)

 

g)

Slide the flue plate clamp over the

 

CND 18” (450 mm)

 

end of the hook/bolt and screw

 

 

 

 

the nut back on to the hook/bolt.

 

 

 

h) Re-install

ceramic

baffles

and

Masonry Fireplace

Combustible Floor

 

the first two (2) front secondary

1" (25mm)

 

 

air

tube

(see

CERAMIC

 

BAFFLE

Non-Combustible Board (K 0.84)

 

 

INSTALLATION).

 

 

 

 

Figure 31: Insert Installation into existing floor level masonry

 

 

 

 

 

 

 

 

 

fireplace.

 

3. There are two (2) leveling legs (shown

 

 

 

 

 

 

in Figure 34), one on each side, at the

 

 

 

back of the unit. Adjust the legs using a

Flue plate

Hook/bolt

 

9/16” wrench to ensure the unit is stable.

clamp

 

 

4. Screw or nail the metal plate provided

Nut

 

 

 

 

by the manufacturer to the inside of the

 

 

 

 

 

 

fireplace.

 

 

 

 

 

 

 

 

METAL TAG: “THIS FIREPLACE HAS BEEN

 

 

ALTERED TO ACCOMMODATE A FIREPLACE

 

 

INSERT AND SHOULD BE INSPECTED BY A

 

 

QUALIFIED PERSON PRIOR TO THE RE-USE

Figure 32: Attaching removable flue.

AS A CONVENTIONAL FIREPLACE.”

 

 

29