Enviro C-10078, 50-645 Installation Instructions, Initial Installation, Qualified Installers Only

Models: 50-645 C-10078 C-11278

1 42
Download 42 pages 28.95 Kb
Page 19
Image 19
INSTALLATION INSTRUCTIONS:

Initial Installation

QUALIFIED INSTALLERS ONLY

INSTALLATION INSTRUCTIONS:

1.Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements.

2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall.

3.Project a line from the center point of the flue outlet upward and outward to the desired flue outlet location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the

wall. Cut the hole from the interior through

Wire

the exterior wall surfaces.

spacers

4. Frame the hole as shown in Figure 29.

 

5.Trim the wall thimble to match the wall thickness as necessary. Install the wall

thimble and secure it to the inner wall

frame using four (4) 1½” wood screws. If

a wall is greater than 8” (203mm) in depth,

the clearance above the flex must be 4⅜”

(111mm)

Figure 26: Wire Spacer in Place.

 

Figure 25: Wire Spacers.

Horizontal Vent Termination

 

6. Apply a bead of Mill-Pac Black

 

sealant to the new Ø4” (10 cm) by

 

5” (12.5 cm) provided flue collar

 

adaptor. Press the flue collar into

 

the flue outlet of the fireplace so

 

that the Mill-Pac seals the flue

 

collar to the flue outlet.

 

7. Stretch both the Ø4” (10 cm) flex

Wall Framing

Wall Thimble

vent and the Ø6⅝” (16.25 cm) flex

Fire Stop

intake liner to the length needed

Exhaust 4" Flex Pipe

to ensure the flex can be easily

 

connected to the vent terminal.

 

8. Slide the Ø6⅝” (16.25 cm) flex

 

intake liner over the flex vent.

Wire Spacers

Install four (4) wire spacers

 

around the flex pipe. Ensure the

 

wire spacers are positioned at

 

either end of the pipes, and at

Combusion Air 6 5/8" Flex Pipe

each end of any elbows in the

 

liners (refer to Figure 25 and 26).

 

 

Flue Pipe Adaptor

 

Figure 27: Installation of Fireplace Horizontal Vent Kit.