Enviro C-10078, C-11278 Secondary Installation, Warning Do Not Install Liner If Unit Is Hot

Models: 50-645 C-10078 C-11278

1 42
Download 42 pages 28.95 Kb
Page 31
Image 31
Secondary Installation

Secondary Installation

Brick Liner Removal:

There are two (2) different brick liner sets; the ceramic set that comes with the unit or the optional cast iron set. The following instructions are for both sets.

WARNING: DO NOT INSTALL LINER IF UNIT IS HOT.

1.Remove glass door (see Maintenance And Service - Glass Door Removal)

2.Carefully remove the log set if it was installed.

3.Ceramic brick liners: Remove the liners: sides, back, then top.

Cast iron brick liners: Remove the baffle by using a T-20 screwdriver to loosen off but not remove the two (2) screws at the back of the baffle lifting up over the back screws then out. Remove the side liners then the back.

4. Ceramic brick liners: If the baffle needs to be removed use a T-20 screwdriver to loosen off but not remove the two (2) screws at the back of the baffle and remove the two (2) screws at the front of the

baffle. Slide the baffle up over

 

the back screws then out.

 

To install the liners follow steps 1

Baffle

 

to 4 in reverse.

 

Important installation notes:

Ensuring the brick liners are flush against the firebox walls.

When sliding the baffle into place making sure to hook the back into place on the two loosened screws.

To install the log set follow the

 

instruction in Log Set and Ember

Back Brick Liner

Installation.

Side Brick Liners

 

 

Figure 43: Cast Iron Brick Liner Installation.

Log Set and Ember Installation:

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner and a few of the logs come with locator pins, notches, and ledges which make alignment easier The andirons and grate must be installed for the logs to be placed properly. Using the pictures provided, carefully set the logs in place (see figures 44 through 48).

NOTE: The logs are fragile and should be handled gently. When removing the logs from their packaging be careful and check that there are 5 large logs (back, left/center, left, right, and center) and 2 small pieces before discarding of the packaging. One log may be covered by cardboard.

Maintenance: Once a year the logs should be removed and checked for deterioration or large amounts of soot. A small amount on the bottom side of the logs is normal. Remove and replace the logs in the same manner described in this section.

If new/more embers and rock wool is required, contact your nearest ENVIRO dealer.

Never operate the fireplace with the glass door removed.

31

Page 31
Image 31
Enviro C-10078, C-11278 Secondary Installation, Warning Do Not Install Liner If Unit Is Hot, Important installation notes