QUALIFIED INSTALLERS ONLY

Planning Your Installation:

The Cara DR is only for horizontal rear vent installations. The maximum horizontal is 2’ (61 cm) and the slope on the vent must be 1¼” per foot (3.2 cm per 30 cm). No vent restrictor is required and no elbows are allowed. When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (25.4 cm); 1½ inches (3.8 cm) clearance to combustibles must be maintained. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory.

Note: If necessary to get above grade the Cara DR can be installed using a 14” or 36” snorkel.

Approved Vent Parts:

Table 5: Approved Vent Manufacturers.

 

Manufacturer

 

 

Trade Name

 

Nominal Sizes

 

 

 

 

 

 

 

 

 

 

 

 

American Metal Products

 

 

AmeriVent Direct

 

4” - 6 5/8”

 

 

 

 

 

 

 

 

 

 

 

 

Security Chimneys International LTD

 

Secure Vent

 

 

4” - 6 5/8”

 

 

 

 

 

 

 

 

 

 

 

 

Selkirk Metalbestos

 

 

Direct-Temp

 

 

4” - 6 5/8”

 

 

 

 

 

 

 

 

 

 

 

 

Simpson Dura-Vent

 

 

Direct Vent GS

 

 

4” - 6 5/8”

 

 

 

 

 

 

 

 

 

 

 

Table 6: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).

 

 

 

 

 

 

 

Direct Vent GS

Direct-Temp

Secure Vent

Ameri Vent Direct

Description

 

 

 

 

 

 

 

 

 

 

908

4DT-6

SV4L6

 

 

6” pipe length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4D7

7” pipe length

 

 

 

 

 

 

 

 

 

 

907

4DT-9

 

 

 

9” pipe length

 

 

 

 

 

 

 

 

906

4DT-12

SV4L12

 

4D12

12” pipe length

 

 

 

 

 

 

904

4DT-24

SV4L24

 

4D2

24” pipe length

 

 

 

 

 

 

 

 

942

4DT-WT

SV4RSN

 

4DWT

Wall thimble

 

 

 

 

 

 

 

 

 

970

4DT-HKA

SV0SHK

 

4DHTK1

Horizontal termination kit (SD: Basic Kit,

 

SEL: Kit A, SC: Standard Kit)

 

 

 

 

 

 

 

 

 

 

 

 

984

4DT-HC

SV4CHC

 

4DHC

Horizontal square termination

 

 

 

 

 

 

 

 

 

 

The Cara DR fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

WARNING: Do not mix parts from different vent manufacturers’ systems. EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance.

15