Enviro C-11500 Initial Installation, Qualified Installers Only, Wire Size, Max. Length

Models: C-11500

1 37
Download 37 pages 41.43 Kb
Page 21
Image 21
Wire Size

Initial Installation

QUALIFIED INSTALLERS ONLY

Electrical Requirements For Gas Valve and Optional Blower:

The ENVIRO CARA will operate without electrical power. This model has a millivolt gas control, which uses the pilot flame to generate enough electricity to operate the main burners. The appliance when equipped with an optional blower must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part

1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the U.S.

 

 

 

 

 

 

 

 

 

ON/OFF

 

Table 9: Recommended Thermostat

 

Optional

Burner Switch

 

 

Wire Size.

 

 

 

 

Remote

Blue Thermocouple

Wire Size

Max. Length

 

Control

 

 

Thermopile

 

14 gauge

100 ft

(30.48 m)

 

Purple

 

Inlet

16 gauge

60 ft

(18.29 m)

 

Manifold

Pressure

 

 

Tap

 

 

Pressure Tap

18 gauge

40 ft

(12.00 m)

 

 

 

 

20 gauge

25 ft

(7.62 m)

 

 

Gas Control

 

22 gauge

18 ft

(5.49 m)

 

Grey

Valve

 

 

 

 

CAUTION: Label

all

wires

prior

70 ° F

 

Optional

 

to disconnection

when

servicing

 

 

Wall Switch

 

controls.

Wiring

errors

can

cause

DOWN

 

Pilot Adjustment

 

 

 

 

 

 

 

 

UP

 

 

improper and dangerous operation.

PROGRAM

 

Screw

 

 

 

 

 

 

 

 

COOL / HEAT

 

 

 

Verify

proper

 

operation

after

 

 

Thermostat

 

servicing.

 

 

 

 

 

Figure 34: Gas Control Valve and Optional Thermostat Wiring.

 

 

 

 

 

 

 

WARNING: Electrical grounding instructions. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard, and must be plugged directly into a properly grounded three-prong outlet.

DO NOT cut or remove the grounding prong from this plug.

ELECTRICAL INFORMATION:

Canadian Installations

The venting system must be installed in accordance with the current CSA B149 installation code and/or local codes having jurisdiction.

U.S.A. Installations

The venting system must be installed in accordance with the current National Fuel Gas Code, ANSI Z223.1, and/or local codes having jurisdiction.

Power

Black

 

Cord

 

Black

Green/White

 

White

 

 

Snap Disk N/O

Green/Yellow

Black

 

 

Fan

Black

Rheostat

 

Black

Figure 35: Wiring Diagram for Electric Fan.