CORNER INSTALLATION:

Initial Installation

QUALIFIED INSTALLERS ONLY

CORNER INSTALLATION:

The dimensions for installing a fireplace in the corner of a room are given below in Figure 11.

 

50 7/8"

 

 

 

 

(1292mm)

21

3/4"

 

 

 

 

(552mm)

15 3/8"

1 1/4"

 

 

 

 

(391mm)

(32mm)

 

 

 

 

 

 

 

 

 

 

36"

 

 

 

 

 

(914mm)

21

1/2"

 

 

 

 

(546mm)

 

 

 

 

13

1/2"

 

45"

 

(343mm)

 

(1143mm)

 

 

 

 

72

3/8"

 

 

 

 

(1838mm)

 

Figure 11. Dimensions for a corner installation.

RAISED FIREPLACES AND HEARTHS:

There are a few options with raised fireplaces: raised with no hearth, raised with a raised hearth, or raised with a floor level hearth. If the fireplace is 4 inches (101 mm) or more above the floor, a hearth is not required. This measurement should be taken from the top of the flooring, i.e. the top of the carpet. The fireplace cannot be placed within 37 inches (940 mm) of the ceiling. When installing a raised fireplace, it is imperative that the support stand is strong enough to hold the weight of the fireplace and venting.

 

 

 

Figure 12. Raised Fireplace with no Hearth

Figure 13. Raised Fireplace with Floor Level Hearth

13

Page 13
Image 13
Enviro DV50DX Initial Installation, Qualified Installers Only, Corner Installation, Raised Fireplaces And Hearths